2021
DOI: 10.1016/j.jneumeth.2021.109075
|View full text |Cite
|
Sign up to set email alerts
|

The construction of an improved model of acute subdural hematoma in rats

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 20 publications
0
2
0
Order By: Relevance
“…The ASDH model was created based on previous methods described by Xian and Zhang 27 , 58 . Briefly, the dura mater was cut at the right craniotomy hole, and an 8-G gavage needle with an external diameter of 1.4 mm was placed close to the craniotomy hole and the surrounding seal was maintained.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The ASDH model was created based on previous methods described by Xian and Zhang 27 , 58 . Briefly, the dura mater was cut at the right craniotomy hole, and an 8-G gavage needle with an external diameter of 1.4 mm was placed close to the craniotomy hole and the surrounding seal was maintained.…”
Section: Methodsmentioning
confidence: 99%
“…In the second part, all rats were performed by the ASHD model and DC model operation successively. Meanwhile, the rats in sham and vehicle group were injected with normal saline (20 ug/g) 30 min after model establishment, and the IFX group rats were administered an intraperitoneal injection of IFX (diluted with normal saline to 2.5 mg/ml, 20 ug/g, cilag Ag) 38 , 58 , 59 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A 450-g copper weight was allowed to fall freely from a height of 2 m through a glass tube onto the centre of a 10-mm metal disc attached between the coronal and lambdoid sutures of the rat, and the rat was immediately removed upon impact to prevent a second impact. Subsequently, SDH was produced by injection in accordance with the method reported by Xian et al [ 10 ]. The dura mater was cut open at the injection site on the right side, and an 8G gavage needle with an external diameter of 1.4 mm was inserted into the cranial hole and under the dura mater.…”
Section: Methodsmentioning
confidence: 99%
“…1b) between the coronal and lambdoid sutures of the rat, and the rat was immediately removed upon impact to prevent a second impact. Subsequently, SDH was produced by injection in accordance with the method reported by Xian et al [10]. The dura mater was cut open at the injection site on the right side, and an 8G gavage needle with an external diameter of 1.4 mm was inserted into the cranial hole and under the dura mater (Fig.…”
Section: Model Constructionmentioning