2018
DOI: 10.1016/j.aca.2018.01.070
|View full text |Cite
|
Sign up to set email alerts
|

The composition of liquid atmospheric pressure matrix-assisted laser desorption/ionization matrices and its effect on ionization in mass spectrometry

Abstract: New liquid atmospheric pressure (AP) matrix-assisted laser desorption/ionization (MALDI) matrices that produce predominantly multiply charged ions have been developed and evaluated with respect to their performance for peptide and protein analysis by mass spectrometry (MS). Both the chromophore and the viscous support liquid in these matrices were optimized for highest MS signal intensity, S/N values and maximum charge state. The best performance in both protein and peptide analysis was achieved employing ligh… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
24
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

4
3

Authors

Journals

citations
Cited by 19 publications
(24 citation statements)
references
References 44 publications
0
24
0
Order By: Relevance
“…Interestingly, DHB has always been preferred to CHCA for the analysis of proteins in solid MALDI, arguably due to its greater ‘softness'. In liquid MALDI MS, other aspects such as proton affinity might have greater influence as this and previously published data suggest 12 …”
Section: Resultsmentioning
confidence: 69%
See 2 more Smart Citations
“…Interestingly, DHB has always been preferred to CHCA for the analysis of proteins in solid MALDI, arguably due to its greater ‘softness'. In liquid MALDI MS, other aspects such as proton affinity might have greater influence as this and previously published data suggest 12 …”
Section: Resultsmentioning
confidence: 69%
“…The same four liquid matrices used for peptide analysis were also investigated for protein analysis. In addition, a fifth liquid matrix that was prepared with CHCA as the only chromophore was also tested, since this was previously found to be superior to the DHB‐based liquid matrix for the detection of larger proteins 12 . For ubiquitin, both the CHCA‐ and DHB‐based liquid MALDI samples performed best with respect to positive ion signal intensities.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The combined lipid and protein MS analyses were performed by liquid AP-MALDI MS [ 21 , 22 , 23 ] on a Synapt G2-Si High Definition Mass Spectrometry (HDMS) mass spectrometer (Waters Corporation) equipped with an in-house developed AP-MALDI source, using a Waters research enabled software (WREnS)-controlled XY stage (Zaber Technologies Inc., Vancouver, Canada). A detailed source description has been reported previously [ 24 ].…”
Section: Methodsmentioning
confidence: 99%
“…This modification to our usual glycerol-based LSM stemmed from recent work optimizing ion signal through substitution of glycerol with other diols. 33…”
Section: Methodsmentioning
confidence: 99%