2008
DOI: 10.1016/j.nima.2008.07.103
|View full text |Cite
|
Sign up to set email alerts
|

The COMPASS RICH-1 fast photon detection system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2008
2008
2011
2011

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…The efficiency of transferring avalanche electrons from stage to stage, does not affect ε effph . 2 Optimal THGEM: t = 0.4 mm , d = 0.3 mm, a = 1 mm; h = 0.01 mm, 3 Value for 1.5 kV/cm photocathode electric field 4 Values for 2kV/cm photocathode electric field Note, that the absolute efficiency of detecting single photons ε photon , e.g. in RICH, depends both on the detector's effective photon detection efficiency ε effph and on the achievable gain (detected pulses above threshold (fp th )).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The efficiency of transferring avalanche electrons from stage to stage, does not affect ε effph . 2 Optimal THGEM: t = 0.4 mm , d = 0.3 mm, a = 1 mm; h = 0.01 mm, 3 Value for 1.5 kV/cm photocathode electric field 4 Values for 2kV/cm photocathode electric field Note, that the absolute efficiency of detecting single photons ε photon , e.g. in RICH, depends both on the detector's effective photon detection efficiency ε effph and on the achievable gain (detected pulses above threshold (fp th )).…”
Section: Discussionmentioning
confidence: 99%
“…The development of advanced imaging Cherenkov detectors is a subject of intensive R&D; examples are novel UV-photon detectors for RICH in CERN-Super LHC-ALICE [1] and CERN-COMPASS [2]. The requirements imposed by these experiments include high sensitivity to single photons, stable operation under intense ionizing-radiation background and the possibility of covering large detection area at low production cost.…”
Section: Introductionmentioning
confidence: 99%
“…The fourth generation detectors, like BaBar-DIRC [6,37], CLEO-III [38][39][40], COMPASS [41][42][43], are all well understood devices, do not present too much operational problems, and are part of the physics analysis of the experiment.…”
Section: Short History Of Riches In Experimentsmentioning
confidence: 99%
“…The upgrade of the COMPASS RICH-1 detector central region required photon detectors and associated electronics allowing trigger rates in the 100 kHz range and beam rates of 100 MHz, corresponding to single channel counting rates of up to several MHz [4][5][6]. These requirements are fulfilled by MaPMTs.…”
Section: Examples Of Applicationsmentioning
confidence: 99%
“…Fused-silica field lens (left) and concentrator lens (centre) used to increase the active area coverage of the MaPMT (right) in COMPASS RICH-1 (from Refs [4][5][6]…”
mentioning
confidence: 99%