2019
DOI: 10.1007/s11051-019-4713-0
|View full text |Cite
|
Sign up to set email alerts
|

The comparison of Pr3+:LaF3 and Pr3+:LiYF4 luminescent nano- and microthermometer performances

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
17
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(18 citation statements)
references
References 52 publications
1
17
0
Order By: Relevance
“…So, Ho, Tm:KLuW sensors synthesized by the modified sol-gel Pechini methodology, CA and MW, have sizes ranging from 150 nm [ 29 ], 16 nm and 12 nm, respectively, and their corresponding maximum S rel are in the range of 0.90% K −1 , 0.33% K −1 and 0.23% K −1 , respectively. Similar results are obtained in the case of Er 3+ , Yb 3+ :NaYF 4 [ 63 ], Er 3+ :Y 2 O 3 [ 64 ], Pr 3+ :LaF 3 and Pr 3+ :LiYF 4 sensors [ 65 ]. It was argued that as the size of the particles decreases, the amount of the luminescent active ions close to their surfaces is increased due to higher surface to volume ratio.…”
Section: Resultssupporting
confidence: 81%
“…So, Ho, Tm:KLuW sensors synthesized by the modified sol-gel Pechini methodology, CA and MW, have sizes ranging from 150 nm [ 29 ], 16 nm and 12 nm, respectively, and their corresponding maximum S rel are in the range of 0.90% K −1 , 0.33% K −1 and 0.23% K −1 , respectively. Similar results are obtained in the case of Er 3+ , Yb 3+ :NaYF 4 [ 63 ], Er 3+ :Y 2 O 3 [ 64 ], Pr 3+ :LaF 3 and Pr 3+ :LiYF 4 sensors [ 65 ]. It was argued that as the size of the particles decreases, the amount of the luminescent active ions close to their surfaces is increased due to higher surface to volume ratio.…”
Section: Resultssupporting
confidence: 81%
“…Pulsed excitation sources operating in the nanosecond regime are frequently used in nanothermometry [7,8], and typical pump sources, such as OPOs or q-switched lasers, are prone to power and energy fluctuations, respectively. As the value of σ abs is wavelength dependent, fluctuations of the emission wavelength can also be treated as energy fluctuations, as can be seen from Equation (5).…”
Section: Influence Of Pump Fluctuations In Pulsed Regimementioning
confidence: 99%
“…However, the pumping regime is mostly overlooked as a potential source of temperature errors although it strongly affects the population densities of the lower energy levels during the measurement. The influence of population densities can be illustrated by comparing the energy level configuration of two commonly used active ions, Erbium (Er 3+ ) [6] and Praseodymium (Pr 3+ ) [7], as depicted in Figure 1a. The combinations of transitions used in Er 3+ nanothermometry are 4 H 11/2 → 4 I 15/2 centered around 525 nm with 4 S 3/2 → 4 I 15/2 centered around 545 nm, therefore including only one lower energy level.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, both the nature of the doped or co-doped lanthanide ions and the architecture of the lanthanide-doped NPs are the tools for tuning their temperature sensitivity [7][8][9][10]19 . However, the temperature sensitivities (S) defined as the rate of change of the thermo-sensitive parameter with temperature are typically low, usually being below 1% K −1 at the temperatures about 300 K for the major part of the reported lanthanide-doped inorganic NPs [7][8][9][10][11]18,19,[25][26][27][28] .…”
mentioning
confidence: 99%