2021
DOI: 10.3390/sym13081461
|View full text |Cite
|
Sign up to set email alerts
|

The Comparison Features of ECG Signal with Different Sampling Frequencies and Filter Methods for Real-Time Measurement

Abstract: Electrocardiogram (ECG) signals have been used to monitor and diagnose signs of cardiovascular disease and abnormal signals about the human body. ECG signals are typically characterized by the PR, QRS, QT interval, ST-segment, and heart rate (HR) parameters. ECG devices are widely used for many applications, especially for the elderly. However, ECG signals are often affected by noises from the environment. There are mainly two types of noises that affect the ECG signals: low frequencies from muscle activity an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 32 publications
0
4
0
Order By: Relevance
“…Then the number of times of irregularity of the distance R-R was recorded by counting the number of times in which the distance difference between every two successive distances was greater than the permissible value of 0.0392 seconds. Then the mean squares of the regularity error of the distance R-R were calculated from the difference's matrix between the matrices, according to 12 :…”
Section: Attribute Extraction Algorithm R-wave Extractionmentioning
confidence: 99%
“…Then the number of times of irregularity of the distance R-R was recorded by counting the number of times in which the distance difference between every two successive distances was greater than the permissible value of 0.0392 seconds. Then the mean squares of the regularity error of the distance R-R were calculated from the difference's matrix between the matrices, according to 12 :…”
Section: Attribute Extraction Algorithm R-wave Extractionmentioning
confidence: 99%
“…In the further sections of the manuscript, the performance of the proposed filter is evaluated using the transfer functions [ 27 ].…”
Section: Validation Of Existing Filter Designsmentioning
confidence: 99%
“…A mix between a band-pass and a band-stop filter, the IIR filter is a hybrid. The transfer functions for an ECG artefact reduction approach [ 13 , 27 ]. It can be observed that the designed two-stage IIR filter has the transfer function of the order 16.…”
Section: Validation Of Existing Filter Designsmentioning
confidence: 99%
“…the number of samples captured for each second [9]. A higher sampling frequency provides a more detailed representation of the ECG signal, by capturing rapid changes in electrical activity allowing for more accurate detection and analysis of cardiac events [10, 11, 12, 6]. Nowdays, the standard ECG sampling rate recommended by the AHA is 500 Hz.…”
Section: Introductionmentioning
confidence: 99%