1988
DOI: 10.1088/0031-8949/1988/t22/039
|View full text |Cite
|
Sign up to set email alerts
|

The CELSIUS Project

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
6
0

Year Published

1988
1988
2015
2015

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…For the specified cell the maximum acceptance is A(β 0 = 0.2 m) ≈ 58 µm (see figure 3). To obtain the required small β-functions, a low-β insertion consisting of four additional quadrupole magnets (blue in figure 4), formerly used at CELSIUS [48], was installed in the drift space in front of and behind the target. The quadrupole magnets are arranged in a doublet structure (DF-FD), where the D and F magnets are powered by separate power supplies.…”
Section: B Low-β Insertionmentioning
confidence: 99%
See 1 more Smart Citation
“…For the specified cell the maximum acceptance is A(β 0 = 0.2 m) ≈ 58 µm (see figure 3). To obtain the required small β-functions, a low-β insertion consisting of four additional quadrupole magnets (blue in figure 4), formerly used at CELSIUS [48], was installed in the drift space in front of and behind the target. The quadrupole magnets are arranged in a doublet structure (DF-FD), where the D and F magnets are powered by separate power supplies.…”
Section: B Low-β Insertionmentioning
confidence: 99%
“…View of the PAX installation at COSY from the interior of the ring (the beam comes from the left). 1: COSY quadrupole magnet, 2: two of the four PAX quadrupoles (formerly used at CELSIUS[48]) forming the low-β insertion by doublet focusing (DF-FD), 3: atomic beam source (ABS), 4: support system, 5: flange supporting rail system, 6: PAX target chamber housing the storage cell. The Breit-Rabi polarimeter (BRP) and the target-gas analyzer (TGA) are mounted towards the outside of the ring.…”
mentioning
confidence: 99%
“…To obtain the required small β-functions, a low-β insertion consisting of four additional quadrupole magnets (blue magnets in Fig. 4), formerly used at CELSIUS [47], was installed in the drift space in front and behind the target. The quadrupole magnets are arranged in a doublet structure (DF-FD), where the D and F magnets are powered by separate power supplies.…”
Section: B Low-β Insertionmentioning
confidence: 99%
“…View of the PAX installation at COSY from the ring interior. 1: COSY quadrupole magnet of a triplet, 2: four PAX quadrupoles (formerly used at CELSIUS[47]), forming the low-β insertion by doublet focusing (DF-FD), 3: Atomic Beam Source (ABS), 4: support system, 5: flange supporting rail system, 6: PAX target chamber housing the storage cell. The Breit-Rabi polarimeter (BRP) and the Target-Gas Analyzer (TGA) are mounted towards the outside of the ring.…”
mentioning
confidence: 99%
“…The WASA detector [19] was, until June 2005, an integrated part of the CELSIUS storage ring. In the measurements presented here, a target of deuterium pellets [20,21] was used, designed for a 4π detector geometry and high luminosity.…”
Section: The Celsius/wasa Experimentsmentioning
confidence: 99%