2018
DOI: 10.1051/epjconf/201817006005
|View full text |Cite
|
Sign up to set email alerts
|

The CdZnTe Detector with Slit Collimator for Measure Distribution of the Specific Activity Radionuclide in the Ground

Abstract: -From 2011 in the NRC "Kurchatov Institute" carry out the dismantling of the MR multiloop research reactor. Now the reactor and all technological equipment in the premises of the reactor were dismantled. Now the measurements of radioactive contamination in the reactor premises are made. The most contaminated parts of premises -floor and the ground beneath it. To measure the distribution of specific activity in the ground the CdZnTe detector (volume 500мм3) was used. Detector placed in a lead shielding with a s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 4 publications
0
1
0
Order By: Relevance
“…The highest values of gamma dose rate around the nozzle. The measurement of the distribution of surface activity inside the vent stack by height was carried out using a collimated CdZnTe detector (Vc=500mm 3 ) with an annular collimator [6] (Fig. 7) The increase dose rate at the approach to the bottom of the vent stack (nozzles) and the uneven distribution of surface activity values along the vent stack height can be explained by the fact that the main contribution to the readings of the devices does not give a contaminated vent stack surface, but a rusty construction inside the vent stack and nozzles.…”
Section: Radiation and Video Survey Of Water Cleanup And Ventilation Systemmentioning
confidence: 99%
“…The highest values of gamma dose rate around the nozzle. The measurement of the distribution of surface activity inside the vent stack by height was carried out using a collimated CdZnTe detector (Vc=500mm 3 ) with an annular collimator [6] (Fig. 7) The increase dose rate at the approach to the bottom of the vent stack (nozzles) and the uneven distribution of surface activity values along the vent stack height can be explained by the fact that the main contribution to the readings of the devices does not give a contaminated vent stack surface, but a rusty construction inside the vent stack and nozzles.…”
Section: Radiation and Video Survey Of Water Cleanup And Ventilation Systemmentioning
confidence: 99%