2016
DOI: 10.1016/j.envres.2016.02.015
|View full text |Cite
|
Sign up to set email alerts
|

The cauliflower-like black crusts on sandstones: A natural passive sampler to evaluate the surrounding environmental pollution

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 38 publications
(24 citation statements)
references
References 48 publications
0
24
0
Order By: Relevance
“…detector) and possible contaminations coming from the XRF analyzer window, 20 repetitive spectra of an instrumental blank (a PTFE block) were acquired before each measurement batch. To determine the presence of the heaviest elements (Z > Ti), the spectra were acquired during 100 s (real time) and the voltage and current of the X-ray tube were set at 40 kV and 15 µA respectively [34,35]. Additionally, to remove the "pinches" Bremsstrahlung and 3rd generation peaks, a 500 µm Al filter was used.…”
Section: Hand-held Energy Dispersive X-ray Fluorescence Spectrometer mentioning
confidence: 99%
“…detector) and possible contaminations coming from the XRF analyzer window, 20 repetitive spectra of an instrumental blank (a PTFE block) were acquired before each measurement batch. To determine the presence of the heaviest elements (Z > Ti), the spectra were acquired during 100 s (real time) and the voltage and current of the X-ray tube were set at 40 kV and 15 µA respectively [34,35]. Additionally, to remove the "pinches" Bremsstrahlung and 3rd generation peaks, a 500 µm Al filter was used.…”
Section: Hand-held Energy Dispersive X-ray Fluorescence Spectrometer mentioning
confidence: 99%
“…3C and 3D). These finding evidences that the particles coming from the marine aerosol 299 can be deposited and trapped in the black crust matrix (Morillas et al 2016a). 300…”
Section: Health 66mentioning
confidence: 89%
“…Analyses were performed under vacuum (20 mbar) in order to improve the detection of the lightest elements, and the lateral resolution used for the spectral acquisitions was 1 mm. Details of the instrument can be checked elsewhere . The Hyper Maps presented in this work were obtained using the M‐Quant software package included in the M4 Tornado software (Bruker Nano GmbH) based on the application of fundamental parameters methods to obtain the quantitative results.…”
Section: Methodsmentioning
confidence: 99%