2008
DOI: 10.1186/cc7021
|View full text |Cite
|
Sign up to set email alerts
|

The 'cardiac-lung mass' artifact: an echocardiographic sign of lung atelectasis and/or pleural effusion

Abstract: Introduction We conducted an ultrasound study to investigate echocardiographic artifacts in mechanically ventilated patients with lung pathology.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 26 publications
0
12
0
Order By: Relevance
“…Echocardiography can significantly alter the management of up to 46% of critically ill patients [1-4]. TTE also offers a noninvasive way to evaluate cardiac function.…”
Section: Introductionmentioning
confidence: 99%
“…Echocardiography can significantly alter the management of up to 46% of critically ill patients [1-4]. TTE also offers a noninvasive way to evaluate cardiac function.…”
Section: Introductionmentioning
confidence: 99%
“…Hyperechoic small structures within consolidation correspond to "air bronchograms" (▶ Fig. 7c) [26]. A positive "dynamic air bronchogram" with centrifugal progression of the air bronchogram signal in inspiration is suggestive of alveolar consolidation instead of bronchial occlusion with subsequent lung collapse and atelectasis [25].…”
Section: Consolidation and Atelectasismentioning
confidence: 99%
“…47,48 Implantable cardiac devices, such as prostheses and pacemaker/ICD leads, are particularly prone to generating these artifacts and can complicate interpretation of echocardiographic images. 47,48 Implantable cardiac devices, such as prostheses and pacemaker/ICD leads, are particularly prone to generating these artifacts and can complicate interpretation of echocardiographic images.…”
Section: Examples Of Beam Width Artifactsmentioning
confidence: 99%
“…This artifact can lead to intra-cavitary clutter and has been misinterpreted in previous studies as thrombi and pseudomasses. 47,48 Implantable cardiac devices, such as prostheses and pacemaker/ICD leads, are particularly prone to generating these artifacts and can complicate interpretation of echocardiographic images. One group, for example, documented an artifact that mimicked the appearance of a pacemaker lead inside the left atrium.…”
Section: Examples Of Beam Width Artifactsmentioning
confidence: 99%