The calibration of a Ge(Li) gamma-ray spectrometer for energy and relative intensity measurements

Abstract: Two aspects of Ge(Li) gamma-ray spectrometry are discussed. The non-linearity of an amplifier-analyzer system was measured using a precision pulser and was checked with gamma-ray standards. The overall accuracy was 2 parts in 104. The relative detection efficiency of gamma-ray full-energy peaks was determined using sources with well measured relative gamma-ray emission rates. Two Ge(Li) detectors with active volumes of 3 cm 2 × 0.5 cm and 4 cm 2 × 0.5 cm were calibrated in the energy range 80-3200 keV. An over… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
1

Year Published

1968
1968
1974
1974

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 55 publications
(6 citation statements)
references
References 13 publications
0
5
0
1
Order By: Relevance
“…The resolution of the system was 3.5 keV at 733 keV for the coaxial detector and 3.0 keV at 733 keV for the trapezoidal detector. The non-linearities in the system were accounted for using the method of Donnelly et al 19). This method gives a measure of the non-linearity associated with the entire electronic system.…”
Section: Experimental Arrangementsmentioning
confidence: 99%
“…The resolution of the system was 3.5 keV at 733 keV for the coaxial detector and 3.0 keV at 733 keV for the trapezoidal detector. The non-linearities in the system were accounted for using the method of Donnelly et al 19). This method gives a measure of the non-linearity associated with the entire electronic system.…”
Section: Experimental Arrangementsmentioning
confidence: 99%
“…A detailed description of the calibrations for energy and intensity measurements is given in ref. 22).…”
Section: Methodsmentioning
confidence: 99%
“…For the purpose of energy determinations, the centroid of the peak area was taken as the definition of the peak position [discussed in ref. 22)]. Gamma-ray energies between 919.5 and 2548.6 keV were determined using the 487.03 and 815.80 keV ?-ray lines in the spectrum for the calibration.…”
Section: Gamma-ray Energy and Relative Intensity Valuesmentioning
confidence: 99%
“…Die Linien der anderen Pdiparate (Refs. [12][13][14][15][16][17]) werden nach dem ,,pair point"-Verfahren nach Donnelly et al [12] in die Kurve eingepagt. Die Megwerte sind in Fig.…”
Section: Eichungunclassified