2014
DOI: 10.1016/j.arth.2013.09.003
|View full text |Cite
|
Sign up to set email alerts
|

The Biomechanical Effect of Increased Valgus on Total Knee Arthroplasty: A Cadaveric Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
16
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(18 citation statements)
references
References 19 publications
2
16
0
Order By: Relevance
“… 28 29 30 In previous studies, the increased MCL tension was one of the principle causes of the pain or stiff knee in internal malrotation. 28 29 30 Internal femoral component rotation and valgus tibial component malalignment may be detrimental to the MCL. For the LCL, PFL, and ALS, the ligament forces increased with external malrotation and varus malalignment.…”
Section: Discussionmentioning
confidence: 95%
See 1 more Smart Citation
“… 28 29 30 In previous studies, the increased MCL tension was one of the principle causes of the pain or stiff knee in internal malrotation. 28 29 30 Internal femoral component rotation and valgus tibial component malalignment may be detrimental to the MCL. For the LCL, PFL, and ALS, the ligament forces increased with external malrotation and varus malalignment.…”
Section: Discussionmentioning
confidence: 95%
“… 27 In malpositioning with valgus malalignment, previous studies reported that strain values from the valgus testing increased in both the anterior and posterior bands of the MCL, with the greatest average values found in the posterior band at 60° knee flexion. 28 …”
Section: Discussionmentioning
confidence: 99%
“…30 Relatively small surgical errors, which lead to slight implant malalignment, may not be detectable using standard follow-up tools and can still lead to considerable differences in foot loading parameters and pressure distribution. 31 Accuracy of prosthetic alignment is an important factor in achieving successful TKA, and it is essential to provide longterm implant survival. 13,21,32 It was reported that knees with varus malalignment had an increased rate of long-term failure with an increased wear of polyethylene inserts, especially for knees aligned in 5 degrees or more varus.…”
Section: Discussionmentioning
confidence: 99%
“…Normal values of component alignment angles15,27,31 and comparison of these angles among the groups created according to tibial component position in frontal plane…”
mentioning
confidence: 99%
“…Consistent with these clinical reports, Bryant and coworkers, in a recent cadaveric study, found valgus loading of a TKA to significantly increase lateral tibio-femoral contact pressures and MCL strain. 50 …”
Section: Tibial Component Varusmentioning