The benefits of mixed-mode chromatography columns for separation of peptides and protein digests

Zuzana Kadlecová,
Hana Boudová,
Květa Kalíková

Abstract: In this work, the evaluation and comparison of mixed-mode chromatography and reversed-phase chromatography for separation of peptides and protein digests have been performed. The effects of pH of aqueous part of mobile phase as well as the effects of organic modifier on retention, resolution, and peak shape were investigated on several columns including three mixed-mode columns possessing reversed-phase/anion-exchange mechanism, two reversed-phase octadecyl columns, and one column with mixed-mode reversed-phas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
0
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 35 publications
0
0
0
Order By: Relevance
“…Aebischer et al developed theoretical models to predict the effectiveness of dilution and determine the minimum dilution value required, if applicable [60]. The theoretical Kadlecová and co-workers demonstrated the benefits of MMC columns for the separation of peptides [54]. They evaluated three MMC columns with RP/anion-exchange mechanisms: two RP octadecyl columns and one column with MMC RP/anion-exchange characteristics only within a defined pH range [54].…”
Section: Two-dimensional Separation Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…Aebischer et al developed theoretical models to predict the effectiveness of dilution and determine the minimum dilution value required, if applicable [60]. The theoretical Kadlecová and co-workers demonstrated the benefits of MMC columns for the separation of peptides [54]. They evaluated three MMC columns with RP/anion-exchange mechanisms: two RP octadecyl columns and one column with MMC RP/anion-exchange characteristics only within a defined pH range [54].…”
Section: Two-dimensional Separation Methodsmentioning
confidence: 99%
“…The theoretical Kadlecová and co-workers demonstrated the benefits of MMC columns for the separation of peptides [54]. They evaluated three MMC columns with RP/anion-exchange mechanisms: two RP octadecyl columns and one column with MMC RP/anion-exchange characteristics only within a defined pH range [54]. They selected a set of peptides varying in polarity, length, amino acid sequence, and charge state, which included dipeptides, N-blocked dipeptides, and oligopeptides [54].…”
Section: Two-dimensional Separation Methodsmentioning
confidence: 99%
See 3 more Smart Citations