2006
DOI: 10.1016/j.injury.2004.09.020
|View full text |Cite
|
Sign up to set email alerts
|

The basket plate in the osteosynthesis of comminuted fractures of distal pole of the patella

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 48 publications
(28 citation statements)
references
References 10 publications
0
27
0
Order By: Relevance
“…No evidence of posttraumatic arthritis or progression of preexisting degenerative patellofemoral joint osteoarthritis was observed. At the final follow-up, Böstman knee scores were excellent in 88 cases (28)(29)(30), good in 55 (20)(21)(22)(23)(24)(25)(26)(27), and unsatisfactory in 13 (<20). According to SF-36 evaluation, the average score was 84.5 (range, 62-91).…”
Section: Resultsmentioning
confidence: 91%
See 1 more Smart Citation
“…No evidence of posttraumatic arthritis or progression of preexisting degenerative patellofemoral joint osteoarthritis was observed. At the final follow-up, Böstman knee scores were excellent in 88 cases (28)(29)(30), good in 55 (20)(21)(22)(23)(24)(25)(26)(27), and unsatisfactory in 13 (<20). According to SF-36 evaluation, the average score was 84.5 (range, 62-91).…”
Section: Resultsmentioning
confidence: 91%
“…The basket plate technique has been described in two clinical reports. 26,27 The plate conforms to the shape of the inferior patellar pole and is secured to the patellar body with superiorly directed screws. Fixed-angle plate osteosynthesis had been described since 2010, as an alternative to tension wiring.…”
Section: Discussionmentioning
confidence: 99%
“…"Basket plates" have been successfully used in clinical practice for fractures of the distal pole of the patella [36]. However, these are not angle-stable and are suitable only for distal pole fractures of the patella.…”
Section: Discussionmentioning
confidence: 99%
“…[12,13] To avoid intrinsic shortcomings of tension wiring, some new internal fixations have been designed and applied in clinical trials such as a fixed angle plate, a locking patella plate and TNSMPC in our study. [17][18][19] The TNSMPC applied in our study was designed according to the anatomic characteristics of patellar and was made of Ti-Ni alloy with high excellent corrosion resistance and desired histocompatibility.…”
Section: Follow-up Assessmentmentioning
confidence: 99%