1989
DOI: 10.1016/0160-4120(89)90061-5
|View full text |Cite
|
Sign up to set email alerts
|

The bake-out of an office building: A case study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0
2

Year Published

1993
1993
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(16 citation statements)
references
References 1 publication
0
14
0
2
Order By: Relevance
“…Sample area 0.000723 m 2 Volume 0.000026 L Loading factor (area of sample/volume, m 2 /m 3 ) 27.81 Air change rate (h −1 ) 9 0 Air supply (mL/min) 39 Equilibration time Sampling after 15-30 min Compounds, sampling flow and total sampling High purity N2 gas perature in an unoccupied but fully furnished building is elevated while some ventilation is maintained [1][2][3]. The principle of this process is to drive the VOCs out of the construction materials by increasing the temperature in the building to 32-40 • C, while increasing the outdoor air exchange so that hazardous gases are emitted from the building.…”
Section: Test Condition Tementioning
confidence: 99%
“…Sample area 0.000723 m 2 Volume 0.000026 L Loading factor (area of sample/volume, m 2 /m 3 ) 27.81 Air change rate (h −1 ) 9 0 Air supply (mL/min) 39 Equilibration time Sampling after 15-30 min Compounds, sampling flow and total sampling High purity N2 gas perature in an unoccupied but fully furnished building is elevated while some ventilation is maintained [1][2][3]. The principle of this process is to drive the VOCs out of the construction materials by increasing the temperature in the building to 32-40 • C, while increasing the outdoor air exchange so that hazardous gases are emitted from the building.…”
Section: Test Condition Tementioning
confidence: 99%
“…Aus anderen Untersuchungen geht hervor, daf gemessene und dutch Modellrechnungen ermittelte Daten fibereinstimmende Ergebnisse erbringen, wie for Dichlormethan [12] und Trichlorethylen [11] gezeigt werden konnte.…”
Section: Probabilistische Sch~tzungenunclassified
“…Im Gegensatz zu Expositionsdaten am Arbeitsplatz oder aus der Umwelt fehlen im Verbraucherbereich mit wenigen Ausnahmen [12] Mel~daten zur H6he der Exposition yon chemischen Stoffen [11,12]. Die Altstoffverordnung der Euro-p/iischen Union sieht bei Fehlen yon Mef~daten eine Sch/itzung unter Verwendung von Modellen vor.…”
unclassified
“…There is debate over three main issues: does bakeout work, is is cost-effective and does it damage the building? The evidence is mixed [55]. Further work is clearly needed before bake-out specifications can be drawn up with confidence.…”
Section: Guidelines For Sound Air-conditioning Systems In Healthy Buimentioning
confidence: 99%