2023
DOI: 10.3390/jcm12196219
|View full text |Cite
|
Sign up to set email alerts
|

The Association of APOE ε4 Allele with Retinal Layer Thickness and Microvasculature in Older Adults: Optic Nerve Decline and Cognitive Change Study

Samran Sheriff,
Ting Shen,
Danit Saks
et al.

Abstract: Purpose: To investigate the relationship between the apolipoprotein E (APOE) ε4 allele and retinal structural and vascular characteristics in older adult participants from several research studies. We also studied the relationship between these structural and vascular characteristics with multifocal visual evoked potential (mfVEP) indices, neuropsychological parameters and MRI brain volumes in these participants. Methods: In this study, 109 participants with a mean (SD) age of 67.1 (9.0) years were recruited. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 48 publications
0
2
0
Order By: Relevance
“…All subjects underwent optical coherence tomography (OCT) peripapillary circular scans at approximately 3.4 mm diameter for retinal nerve fibre layer (RNFL) thickness measures and macular posterior pole scan for ganglion cell-inner plexiform layer (GCIPL) thickness (Spectralis HRA + OCT; Heidelberg Engineering, Heidelberg, Germany, Version 4.0) [27]. Scans with a quality score of <15 were excluded from the analysis as recommended by the Heidelberg guideline.…”
Section: Oct and Octa Acquisition And Processingmentioning
confidence: 99%
See 1 more Smart Citation
“…All subjects underwent optical coherence tomography (OCT) peripapillary circular scans at approximately 3.4 mm diameter for retinal nerve fibre layer (RNFL) thickness measures and macular posterior pole scan for ganglion cell-inner plexiform layer (GCIPL) thickness (Spectralis HRA + OCT; Heidelberg Engineering, Heidelberg, Germany, Version 4.0) [27]. Scans with a quality score of <15 were excluded from the analysis as recommended by the Heidelberg guideline.…”
Section: Oct and Octa Acquisition And Processingmentioning
confidence: 99%
“…Scans were assessed and automatic segmentation of the RNFL, GCL and IPL were reviewed by two assessors (TS and SS) for OCT and by (AS and DS) for OCTA, and poor-quality images or those with artefacts were excluded from statistical analysis. An internal 6 × 6 grid was analysed from the posterior pole macular thickness map, as described previously [27,28]. The vessel density (VD) and vascular feature analyses were conducted utilising ImageJ software (National Institutes of Health, available at https://imagej.net/Fiji/Downloads) with a method adapted from Elfarnawany et al [21,29,30].…”
Section: Oct and Octa Acquisition And Processingmentioning
confidence: 99%