1992
DOI: 10.1016/0360-3016(92)90315-9
|View full text |Cite
|
Sign up to set email alerts
|

The associated targets methodology and the multi-isocenters radiosurgery treatment planning ARTEMIS-3D

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

1995
1995
2002
2002

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 0 publications
0
10
0
Order By: Relevance
“…The ARTEMIS 3D stereotactic radiotherapy dose calculation software was first developed on a VaxStation DEC 3200 in the VMS environment and then adapted to a more powerful computer, the DecStation 5000/240 (DEC) in the Unix environment. The programming languages are FORTRAN and C (21)(22)(23). The ARTEMIS 3D permits both qualitative evaluation such as isodose displays or dose-distribution profiles, and quantitative evaluation, such as dose-volume histograms.…”
Section: Methodsmentioning
confidence: 99%
“…The ARTEMIS 3D stereotactic radiotherapy dose calculation software was first developed on a VaxStation DEC 3200 in the VMS environment and then adapted to a more powerful computer, the DecStation 5000/240 (DEC) in the Unix environment. The programming languages are FORTRAN and C (21)(22)(23). The ARTEMIS 3D permits both qualitative evaluation such as isodose displays or dose-distribution profiles, and quantitative evaluation, such as dose-volume histograms.…”
Section: Methodsmentioning
confidence: 99%
“…The main components of the stereotactic sitting position irradiation technique for which this study has been carried out are: a) an isocentric linear accelerator with a set of circular secondary collimators with diameters ranging from 6 mm to 20 mm in steps of 2 mm; b) a Betti (17) special moveable chair incorporating a stereotactic frame of Talairach (18); c) anatomical data obtained from stereotactic angiography, CT and MRI imaging; and d) our computerized treatment planning system ARTEMIS-3D and SVD optimization algorithm, which were firstly developed on a Vaxstation 3200 (Digital Company) in the VMS environment and the last version ARTEMIS-3D/Dosigray adapted to a more powerful computer the Dec station 5000/240 (Digital Company) in the ULTRIX 4.3 environment (19).…”
Section: The Con6ergent Multi-arcs Stereotactic Irradiationmentioning
confidence: 99%
“…6 , 104-113 (1995) each voxel of the three-dimensional matrix; w is the weighting vector containing each beam weight; and M is the minibeam transmission matrix. The elements of M are computed using the ARTEMIS-three-dimensional software [12,13,15,191 using the experimental data of percentage depth doses (PDD), the profiles at different practical source skin distances (SSD), tissue maximum ratios (TMR), and collimator factor data. All minibeams contained into M are calculated for a weight equal to one.…”
Section: Modeling Radiosurgical Dose Distributionmentioning
confidence: 99%