2020
DOI: 10.1016/j.earlhumdev.2020.105160
|View full text |Cite
|
Sign up to set email alerts
|

The assessment of the fetal heart function using two-dimensional speckle tracking with a high frame rate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(21 citation statements)
references
References 14 publications
4
10
0
Order By: Relevance
“…In human fetuses, RV global longitudinal strain shows less deformation with advancing gestational age. 18 This is proposed to reflect increased RV afterload, that is, fetal blood pressure that increases with advancing gestation. In the present study, fetal MAP decreased during hypoxemia; thus, the effect of reduced afterload on RV global longitudinal strain should have been the opposite.…”
Section: Results In the Context Of What Is Knownmentioning
confidence: 99%
“…In human fetuses, RV global longitudinal strain shows less deformation with advancing gestational age. 18 This is proposed to reflect increased RV afterload, that is, fetal blood pressure that increases with advancing gestation. In the present study, fetal MAP decreased during hypoxemia; thus, the effect of reduced afterload on RV global longitudinal strain should have been the opposite.…”
Section: Results In the Context Of What Is Knownmentioning
confidence: 99%
“…Of these, three studies showed an increase in LV‐GLS and RV‐GLS values throughout gestation 38,44,52 , similar to the current study. Other studies reported stable strain values in both ventricles 13,39,40,42,43,48,51,53,54 , increased LV‐GLS values only 37 or increased RV‐GLS values only 36,45,47,49 . The discrepancies among studies can be explained by the differences in ultrasound device and speckle‐tracking software used.…”
Section: Discussionmentioning
confidence: 97%
“…Compared with conventional echocardiography, STE technology can more sensitively evaluate the mechanics and proving that the assessment of fetal myocardial strain is feasible and repeatable. 3,10,11 The global longitudinal strain parameters of the fetal heart obtained from the fetal four-chamber view are reportedly the most reliable deformation parameters that reflect fetal heart function. 12 Therefore, in this study, the four-chamber view of the fetus was selected for aCMQ to obtain longitudinal strain-related parameters and explore their clinical value.…”
Section: Discussionmentioning
confidence: 99%
“…Compared with conventional echocardiography, STE technology can more sensitively evaluate the changes in cardiac function in adults and children by acquiring myocardial deformation parameters 8,9 . With the development of ultrasound imaging technology, focus has moved to the analysis of fetal myocardial mechanics and proving that the assessment of fetal myocardial strain is feasible and repeatable 3,10,11 …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation