2020
DOI: 10.1088/1742-6596/1679/4/042050
|View full text |Cite
|
Sign up to set email alerts
|

The assessment of stressed-deformed state of tube bundle of the heat-exchange apparatus with the fixed pipe grids

Abstract: Ensuring reliable operation of heat exchange equipment is the key to continuous and efficient operation of the entire technological unit or assembly as a whole. During installation, repair or operation, various deviations of the construction elements of the heat exchangers from the values specified by the project are possible. One of the possible scenarios of such deviations is the deviation of the transverse baffles of the tube bundle from the vertical design position during installation. Since the transverse… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 13 publications
0
2
0
Order By: Relevance
“…Paidoussis et al [8][9][10] reviewed the dynamical behavior of pipes conveying fluid under different boundary conditions and pointed out that a cantilevered pipe would be subjected to flutter instability when the internal flow velocity becomes sufficiently high. For heat-exchange bundle structures existing in the nuclear industry, beyond the onset of flutter instability, the pipe would be subjected to periodic motion and might contact the surrounding supporting plates or pipes [11][12][13]. In this case, the effect of contact and possible dry friction between the pipe and the surrounding structures may be pronounced.…”
Section: Introductionmentioning
confidence: 99%
“…Paidoussis et al [8][9][10] reviewed the dynamical behavior of pipes conveying fluid under different boundary conditions and pointed out that a cantilevered pipe would be subjected to flutter instability when the internal flow velocity becomes sufficiently high. For heat-exchange bundle structures existing in the nuclear industry, beyond the onset of flutter instability, the pipe would be subjected to periodic motion and might contact the surrounding supporting plates or pipes [11][12][13]. In this case, the effect of contact and possible dry friction between the pipe and the surrounding structures may be pronounced.…”
Section: Introductionmentioning
confidence: 99%
“…Even small displacements can have a decisive effect on the stress-strain state (SDS) of the piping. When acceptance of installation works with the presence of installation deviations of equipment, the SDS assessment of its piping is usually not carried out [4][5][6].…”
Section: Introductionmentioning
confidence: 99%