2019 Scientific Meeting on Electrical-Electronics &Amp; Biomedical Engineering and Computer Science (EBBT) 2019
DOI: 10.1109/ebbt.2019.8741668
|View full text |Cite
|
Sign up to set email alerts
|

The artifacts of human physical motions on vital signs monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 17 publications
0
8
0
Order By: Relevance
“…A minimum error rate of 4.6% was achieved as was compared to the standard ECG measurement for the moving state of a human body. In another study [81], the authors analyzed the effect of body movements, such as hand motion and lips movement during speaking. A mathematical model and experimental results are given for stationary as well as non-stationary cases.…”
Section: Vital Signs Of a Non-stationary Subjectmentioning
confidence: 99%
“…A minimum error rate of 4.6% was achieved as was compared to the standard ECG measurement for the moving state of a human body. In another study [81], the authors analyzed the effect of body movements, such as hand motion and lips movement during speaking. A mathematical model and experimental results are given for stationary as well as non-stationary cases.…”
Section: Vital Signs Of a Non-stationary Subjectmentioning
confidence: 99%
“…CW [1], [3], [8], [20], [21], [22], [23], [24], [25], [26], [27], [28], [29], [30], [31], [32], [33], [34], [35] UWB-IR [2], [10], [21], [36], [37], [38], [39], [4], [40], [41], [42], [43], [44], [45], [46], [47], [48], [49], [50] FMCW [8], [7], [51], [52], [53], [54], SFCW [2], [9], [55], [56], [57] [58] A. CW Radar The authors in [1] used a CW Doppler and a pulse radar to wirelessly detect heart signal and breathing signal. Several sources of signal distortion were also...…”
Section: Radar Type Referencementioning
confidence: 99%
“…Meanwhile, the effects of speech and hand movements on the measurement of respiration signal using an UWB radar was studied in [39]. It can be observed that the noise from these activities affected the accuracy of the target signal.…”
Section: B Uwb Impulse Radarmentioning
confidence: 99%
See 1 more Smart Citation
“…The human chest exhibits periodic movement, as shown by ( 6) and (7), and will induce the shift of the signal along the slow-time domain. From [22][23][24][25][26][27][28][29][30][31][32][33][34][35][36][37][38][39], the vital sign spectrum Y(t 0 ,f ) is defined as the Fourier transform of the received signal in its slow-time domain that is…”
Section: Detection Block Diagrammentioning
confidence: 99%