Abstract:This paper presents the experimental techniques of transmission electron microscopy of plasma-spray powder alloy coatings. It includes the specimen preparation techniques for powder materials and for plasma spray powder coatings from the nickel-chromium-based alloy and synthetic hydroxyapatite (HA) and the analysis of the results. The study of the structure-phase compositions of HA powders and HA and Ni-Cr-based plasma spray coatings has been carried out by using transmission electron microscopy on JEM-2100 (J… Show more
“…Electron diffraction patterns of specimens of HA powder were obtained by transmission electron microscopy (TEM) on JEM-2100 (JEOL). TEM specimen preparation techniques are described in detail in a previous paper [30]. Ten TEM images were analyzed, and an average of five diffraction patterns were used to calculate the crystal lattice parameters.…”
This paper presents new results of microplasma spraying (MPS) of laboratory-synthesized hydroxyapatite (HA) powder coatings onto trabecular substrates obtained by selective laser melting (SLM) of a certified titanium medical alloy powder. The aim of the study was to establish the possibility of combining the technologies of MPS and additive manufacturing (AM) for the possible production of custom-designed implants with increased surface biocompatibility, as well as to establish the MPS parameters that ensure chemical purity of the HA coating and satisfactory adhesion of the coatings to the substrate. The structural-phase compositions of the initial HA powder and the plasma-sprayed HA coating were studied by X-ray diffraction analysis and transmission electron microscopy, and the adhesion strength of the coating was tested according to the F1147 standard of the American Society for Testing and Materials (ASTM). The main results of the study are the following: the application of the MPS technology for HA coating with an average thickness of 150±50 μm on trabecular substrates obtained by the SLM method has been shown. The parameters of MPS of HA coatings onto titanium implants with a trabecular surface have been established. It is also proved that using the appropriate MPS parameters, it is possible to obtain a HA coating with a 95% level of HA phases, 93% level of crystallinity, and the adhesion strength to the trabecular substrate of 24.7±5.7 MPa, which complies with the requirements of the international medical standard (International Organization for Standardization [ISO] 13779-2:2018). These results are of significance for a wide range of researchers developing plasma spray technologies for the manufacture of biocompatible coatings.
“…Electron diffraction patterns of specimens of HA powder were obtained by transmission electron microscopy (TEM) on JEM-2100 (JEOL). TEM specimen preparation techniques are described in detail in a previous paper [30]. Ten TEM images were analyzed, and an average of five diffraction patterns were used to calculate the crystal lattice parameters.…”
This paper presents new results of microplasma spraying (MPS) of laboratory-synthesized hydroxyapatite (HA) powder coatings onto trabecular substrates obtained by selective laser melting (SLM) of a certified titanium medical alloy powder. The aim of the study was to establish the possibility of combining the technologies of MPS and additive manufacturing (AM) for the possible production of custom-designed implants with increased surface biocompatibility, as well as to establish the MPS parameters that ensure chemical purity of the HA coating and satisfactory adhesion of the coatings to the substrate. The structural-phase compositions of the initial HA powder and the plasma-sprayed HA coating were studied by X-ray diffraction analysis and transmission electron microscopy, and the adhesion strength of the coating was tested according to the F1147 standard of the American Society for Testing and Materials (ASTM). The main results of the study are the following: the application of the MPS technology for HA coating with an average thickness of 150±50 μm on trabecular substrates obtained by the SLM method has been shown. The parameters of MPS of HA coatings onto titanium implants with a trabecular surface have been established. It is also proved that using the appropriate MPS parameters, it is possible to obtain a HA coating with a 95% level of HA phases, 93% level of crystallinity, and the adhesion strength to the trabecular substrate of 24.7±5.7 MPa, which complies with the requirements of the international medical standard (International Organization for Standardization [ISO] 13779-2:2018). These results are of significance for a wide range of researchers developing plasma spray technologies for the manufacture of biocompatible coatings.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.