The application of infrared spectroscopy to breath CO2isotope ratio measurements and the risk of spurious results

Abstract: Stable CO2 isotope breath tests are established as a valuable tool in diagnostic and investigative medicine with the potential to become more prominent in the future. However, their development and widespread clinical use is limited by the requirement of isotope ratio mass spectroscopic analysis. To overcome this restriction alternative analytical techniques have been developed; the most promising, offering relative simplicity and lower costs, are those instruments using infrared spectroscopy. Clinical investi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

2002
2002
2012
2012

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 78 publications
(111 reference statements)
0
10
0
Order By: Relevance
“…Infrared (IR) spectroscopy has frequently been employed for the determination of isotope ratio 13 C/ 12 C for CO 2 in breath tests (Mansfield & Rutt, 1998; Adamek et al, 1999; Braden, Caspary, & Lembcke, 1999; Esler et al, 2000; Crosson et al, 2002). IR spectroscopy provides a simple method for isotope ratio measurement, but it has a narrow window to detect isotopes.…”
Section: Advances In the Measurements Of Stable Isotope‐labeled Mmentioning
confidence: 99%
“…Infrared (IR) spectroscopy has frequently been employed for the determination of isotope ratio 13 C/ 12 C for CO 2 in breath tests (Mansfield & Rutt, 1998; Adamek et al, 1999; Braden, Caspary, & Lembcke, 1999; Esler et al, 2000; Crosson et al, 2002). IR spectroscopy provides a simple method for isotope ratio measurement, but it has a narrow window to detect isotopes.…”
Section: Advances In the Measurements Of Stable Isotope‐labeled Mmentioning
confidence: 99%
“…They evaluate differences in thermal expansion within reference chambers containing 13 CO 2 and 12 CO 2 , respectively, which is induced by absorption of infrared radiation. According to this, NDIRS‐based devices are described more accurately as infrared ratiometers [7]. The infrared radiation has to pass the chamber containing the gas sample before reaching the 13 CO 2 or 12 CO 2 measuring chambers, respectively, where it induces thermal expansion because of absorption.…”
Section: Discussionmentioning
confidence: 99%
“…Thus, not only influences from spectral interference by breath test compounds with an absorption band that coincides with the band of interest, but changes in gas compounds or their concentrations may be misinterpreted as a variation in the carbon isotope ratio. Mansfield and Rutt reviewed systematically the literature for influences of more than 200 detected breath compounds on infrared spectroscopy for CO 2 isotope ratio measurement [7]. They identified five compounds which could influence the measurement but with little significance in clinical practice (including the well‐known effect of N 2 O).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The IR window of 4.3 µm was chosen for performing measurements due to the strong absorption of CO 2 ν 3 mode. A comprehensive study of the various possible interfering compounds present in human exhaled breath was published by Mansfield 19 and it showed that this particular IR region was free from all coincident absorption bands. Figure 1 presents an overall schematic of the instrument.…”
Section: Methodsmentioning
confidence: 99%