2005
DOI: 10.1016/j.polymdegradstab.2005.01.030
|View full text |Cite
|
Sign up to set email alerts
|

The application of a novel profluorescent nitroxide to monitor thermo-oxidative degradation of polypropylene

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
52
0

Year Published

2005
2005
2015
2015

Publication Types

Select...
4
2

Relationship

3
3

Authors

Journals

citations
Cited by 64 publications
(53 citation statements)
references
References 26 publications
1
52
0
Order By: Relevance
“…Notably after 30 h, significant fluorescence could be detected, yet the polymer displayed no visible indication of degradation. This mirrors the performance in thermooxidative degradation [11] where profluorescent nitroxides impart stability into the polymer matrix and signal the levels of radical degradation reactions occurring. Notably there was no increase in fluorescence from polypropylene blanks photolysed under the same conditions.…”
Section: Resultsmentioning
confidence: 84%
See 2 more Smart Citations
“…Notably after 30 h, significant fluorescence could be detected, yet the polymer displayed no visible indication of degradation. This mirrors the performance in thermooxidative degradation [11] where profluorescent nitroxides impart stability into the polymer matrix and signal the levels of radical degradation reactions occurring. Notably there was no increase in fluorescence from polypropylene blanks photolysed under the same conditions.…”
Section: Resultsmentioning
confidence: 84%
“…To demonstrate the application of TMAO as a probe, it was incorporated into polypropylene at low levels (Ͻ0.05 %) by using established methodology. [11] The polymer was irradiated in a Heraeus Sun Test CPS+ at an energy of Figure 3. Notably after 30 h, significant fluorescence could be detected, yet the polymer displayed no visible indication of degradation.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The cleavage of the covalent connection between both moieties would negate the quenching performance. 128 Therefore, the connection of commercially available nitroxides and fluorophores via esterification, 122,123,[129][130][131][132][133][134] amidation, [135][136][137] or sulfonamidation [138][139][140] employed in the early stages of the PFN research are less suitable for efficient PFNs (refer to Scheme 10). The resulting compounds contain long, hydrolysis sensitive linkages.…”
Section: Synthesismentioning
confidence: 99%
“…158 Thermal polymer degradation has also been investigated extensively, including studies on initiator free, 128 as well as AIBN 159 and peroxide 144 doped polymer samples.…”
Section: Figurementioning
confidence: 99%