The Applicability of Molecular Descriptors for Designing an Electrospray Ionization Mass Spectrometry Compatible Library for Drug Discovery

Abstract: Detecting a small molecular-weight compound by electrospray ionization mass spectrometry (ESI-MS) requires the compound to obtain a charge. Factors such as gas-phase proton affinities and analyte surface activity are correlated with a positive ESI-MS response, but unfortunately it is extremely challenging to predict from a chemical structure alone if a compound is likely to yield an observable molecular-ion peak in an ESI-MS spectrum. Thus, the design of a chemical library for an ESI-MS ligand-affinity screen … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 57 publications
0
6
0
Order By: Relevance
“…MS also boasts higher resolution (∼10 3 -10 4 ) and dynamic range (∼10 3 -10 4 ). Conversely, MS only detects metabolites that readily ionize, as a result of which upwards of 40% of chemical libraries are not observable by MS [37, 38]. Similarly, ion suppression is a well-known problem in MS, which further reduces the detection of ions of interest due to matrix effects [39].…”
Section: Introductionmentioning
confidence: 99%
“…MS also boasts higher resolution (∼10 3 -10 4 ) and dynamic range (∼10 3 -10 4 ). Conversely, MS only detects metabolites that readily ionize, as a result of which upwards of 40% of chemical libraries are not observable by MS [37, 38]. Similarly, ion suppression is a well-known problem in MS, which further reduces the detection of ions of interest due to matrix effects [39].…”
Section: Introductionmentioning
confidence: 99%
“…However, several attempts of MS spectra modelling appeared in the literature. Two major approaches can be distinguished, namely, predicting MS spectra features using quantum-chemical computations (Cautereels et al 2016;Ásgeirsson et al 2017;Spackman et al 2018) and 2D structure and topology-based methods (Gray et al 1980;Gasteiger et al 1992;Copeland et al 2012). The latter approach can be regarded as an extension of popular fragmentation rules.…”
Section: Discussionmentioning
confidence: 99%
“…Noteworthy, in many cases, there are no reference standards and no reference spectra available in the literature. There have been several attempts to use theoretical models for EI-MS spectra analysis (Gray et al 1980;Gasteiger et al 1992;Copeland et al 2012;Ásgeirsson et al 2017;Spackman et al 2018). According to our best knowledge, 1D and 2D descriptor-based models devoted to the organochlorine compounds have never been reported in the literature.…”
Section: Introductionmentioning
confidence: 99%
“…In contrast, MS depends on compound ionization and volatility. A number of metabolites do not produce a detectable molecular ion [224]. Moreover, the heterogeneity and complexity of the metabolome may lead to additional ion suppression and further diminish the detection of weakly ionizable metabolites.…”
Section: Discussionmentioning
confidence: 99%