2009
DOI: 10.1016/j.ejvs.2009.08.007
|View full text |Cite
|
Sign up to set email alerts
|

The Anaconda™ AAA Stent Graft System: 2-Year Clinical and Technical Results of a Multicentre Clinical Evaluation

Abstract: The design features of the second-generation Anaconda AAA Stent Graft System are effective in the treatment of AAAs on mid-term evaluation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
38
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 50 publications
(38 citation statements)
references
References 20 publications
(11 reference statements)
0
38
0
Order By: Relevance
“…However, the outcomes with newer generation devices with different device profiles and attachment mechanisms when placed outside the IFU are unknown for EVAR. [13][14][15][16][17][18][19] In our present series, we used the Endurant stent graft in patients with normal and hostile aortoiliac anatomy. This new-generation device obtained the Conformité Européene mark in July 2008 and is commercially available in all European countries.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the outcomes with newer generation devices with different device profiles and attachment mechanisms when placed outside the IFU are unknown for EVAR. [13][14][15][16][17][18][19] In our present series, we used the Endurant stent graft in patients with normal and hostile aortoiliac anatomy. This new-generation device obtained the Conformité Européene mark in July 2008 and is commercially available in all European countries.…”
Section: Discussionmentioning
confidence: 99%
“…11,12 During the last years, new grafts have been proposed to expand the indications for EVAR to patients with a hostile anatomy of the proximal aortic neck. [13][14][15] First-generation stent grafts relied on a variety of proximal attachments, including radial force, suprarenal stents, barbs, and columnar strength. The need to treat high-risk patients with a hostile aortic neck anatomy extended the use of the stent grafts even in off-label (OL) situations, but the applications outside of anatomically specific instructions for use (IFU) seem to affect the long-term results of these first-generation devices.…”
mentioning
confidence: 99%
“…The Anaconda AAA stent-graft system and implantation procedure have been extensively described elsewhere. 6 , 8 , 17 In short, the Anaconda stent-graft is a repositionable 3-piece endovascular graft for infrarenal fixation and consists of a woven polyester graft supported by independent nitinol ring stents that each comprise a single strand of wound nitinol wire, that is, a wire bundle ( Figure 1 ). The proximal part of the main body consists of a self-expanding dual ring, which assumes the shape of a “saddle” when oversized and constrained against the aortic wall.…”
Section: Methodsmentioning
confidence: 99%
“…The Anaconda AAA stent-graft (Vascutek, a Terumo company, Inchinnan, Scotland) is a self-expanding infrarenally fixating device with a proximal dual ring design that assumes a saddle shape with peaks and valleys when oversized and deployed in the aortic neck ( Figure 1 ). The initial design of Lauterjung in 1996 has evolved to a device with favorable midterm results, 6 8 even in severely angulated anatomy. 9 , 10 From clinical observations, it appears that over time the rings expand and the saddle shape flattens.…”
Section: Introductionmentioning
confidence: 99%
“…Since this was a new technique, we decided to employ a repositionable ASG to ensure LoRA patency at the end of the procedure. 3 IVUS has been proposed as an imaging diagnostic technique that can provide useful information during endovascular stent graft repair. 4,5 Unlike traditional arteriography, IVUS provides the real-time visualisation of the vascular findings.…”
mentioning
confidence: 99%