2021
DOI: 10.1016/j.foodcont.2021.108241
|View full text |Cite
|
Sign up to set email alerts
|

The ameliorative effects of low-temperature pasteurization on physicochemical and microbiological quality of raw Akoya pearl oyster (Pinctada fucata)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(11 citation statements)
references
References 46 publications
2
9
0
Order By: Relevance
“…Drastic increment in TVB-N values of microwave treated sample can be seen at day 5 which paralleled with the increase in microbial counts which nally reaching beyond acceptable limit of 30 mg N/100 g. TVB-N is a common parameter to measure the post-mortem decomposition on both protein and non-protein nitrogenous compound from the degradation caused by the microbial activity and endogenous proteolytic enzymes pH Figure 6c shows the pH changes of untreated and treated shucked oysters comparing SS with microwave treatment during 20 days of refrigerated storage. The pH of freshly treated samples was at 6.5 for the control and microwave treatment, which is within the range of pH values for freshly shucked oysters (generally between 6.2 and 6.6) (Chung et al, 2021). The freshly treated SS sample was signi cantly higher at pH 6.6 at day 0.…”
Section: Total Volatile Basic Nitrogen (Tvb-n)supporting
confidence: 56%
See 2 more Smart Citations
“…Drastic increment in TVB-N values of microwave treated sample can be seen at day 5 which paralleled with the increase in microbial counts which nally reaching beyond acceptable limit of 30 mg N/100 g. TVB-N is a common parameter to measure the post-mortem decomposition on both protein and non-protein nitrogenous compound from the degradation caused by the microbial activity and endogenous proteolytic enzymes pH Figure 6c shows the pH changes of untreated and treated shucked oysters comparing SS with microwave treatment during 20 days of refrigerated storage. The pH of freshly treated samples was at 6.5 for the control and microwave treatment, which is within the range of pH values for freshly shucked oysters (generally between 6.2 and 6.6) (Chung et al, 2021). The freshly treated SS sample was signi cantly higher at pH 6.6 at day 0.…”
Section: Total Volatile Basic Nitrogen (Tvb-n)supporting
confidence: 56%
“…Martin et al (2007) studied the application of high steam injection with and without pre-heating and holding prior to ice water immersion with 85% muscle release of raw like oyster meat reported reduction in TPC not greater than one log difference from the untreated samples after 14 days storage at 2 C. Andrews et al (2000) noted that the application of pasteurization at 50 ℃ for 0 to 15 min on the oysters which stored at chilled condition for 14 days had an inconsistent trend on TPC within 2 logs. Chung et al (2021) reported longer pasteurization (50 ℃) of oysters to 20 min with lower uctuation of TPC between 50 to 2.3x10 4 CFU/g for 14 days refrigerated storage. When comparing with other studies, the SS treatment is e cient to reduce the microbial load of the shucked oysters during refrigerated storage up to 20 days.…”
Section: Total Plate Countmentioning
confidence: 94%
See 1 more Smart Citation
“…The initial TVC for oysters is usually 2-4 log (CFU/g), usually depending on their growing environment (Chung et al, 2021). The initial value of TVC in oysters transported to the laboratory was 2.3 log (CFU/g).…”
Section: Tvcmentioning
confidence: 99%
“…After homogenization of the meat (any liquor present in the shell was discarded), the microbial count was determined in 10 -1 to 10 -6 dilutions of the homogenates. Aerobic plate counts were determined by the pour plate method using Plate Count Agar (3M Petrifilm, USA) incubated at 30±1°C for 72±3 h (Chung et al, 2021). Microbiological data were transformed into logarithms of the number of colony-forming units (CFU/g).…”
Section: Microbiological Analysismentioning
confidence: 99%