2018
DOI: 10.1016/j.molstruc.2017.09.082
|View full text |Cite
|
Sign up to set email alerts
|

The acidic pH-induced structural changes in apo-CP43 by spectral methodologies and molecular dynamics simulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 19 publications
(15 citation statements)
references
References 51 publications
0
13
0
Order By: Relevance
“…The assessment of the backbone Cα-RMSD value for each target–EGCG system is used to measure the structural stability in the MD simulation [51,52] as shown in Figure 6. As shown, most of the systems reached equilibrium after 5 ns when running a MD simulation with an average backbone Cα-RMSD of about 3 Å.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The assessment of the backbone Cα-RMSD value for each target–EGCG system is used to measure the structural stability in the MD simulation [51,52] as shown in Figure 6. As shown, most of the systems reached equilibrium after 5 ns when running a MD simulation with an average backbone Cα-RMSD of about 3 Å.…”
Section: Resultsmentioning
confidence: 99%
“…The systems first had their energy minimized using the steepest descent minimization method to limit the energy to 1000 Kcal/mol/nm [69]. Before the formal simulation, the complex system was carried out at both 100 ps NVT and NPT ensemble with 300 K temperature and 1 atm pressure [22,51]. The long-range electrostatic interactions were calculated using the PME (Particle Mesh Ewald) method and the hydrogen bonds were constrained using the LINCS (Linear Constraint Solver) algorithm.…”
Section: Methodsmentioning
confidence: 99%
“…2A, the fluorescence intensity of Pin1-WT decreased gradually with the increase of temperature, data of mutants not shown, which indicated that the polarity around the tryptophan residues gradually increased in the unfolded process. Ordinarily, the F 350 /F 335 ratio was used to reflect the changes in the λ max of the fluorescence spectra (λ max = max emission wavelength) 11,22 . The increase of F 350 /F 335 ratio meant red-shift of λ max , conversely, the decrease of the ratio indicated blue-shift of λ max .…”
Section: Resultsmentioning
confidence: 99%
“…RMSF value is considered as the criterion of the overall flexibility in MD simulation [38,39]. Moreover, we also investigated the motion of key residues of FXIIa interacted with inhibitors [35].…”
Section: Analysis Of the Admet Predictionmentioning
confidence: 99%