2010
DOI: 10.1016/j.ygyno.2009.10.072
|View full text |Cite
|
Sign up to set email alerts
|

The accuracy of the sentinel lymph node concept in early stage squamous cell vulvar carcinoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
19
0
3

Year Published

2011
2011
2018
2018

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(22 citation statements)
references
References 30 publications
0
19
0
3
Order By: Relevance
“…In such cases, only the sensitivity and specificity results can be given for the combination of tests used rather than only blue dye or 99m Tc separately or only both used together in all patients. However, for the other 20 studies, 50,51,[53][54][55][56][57][58][59][60][61][63][64][65][68][69][70][71][72][73][74] detection rates per groin can be given for each test separately and both tests combined (see Table 7). It is noticeable that the histopathological techniques used for the full IFL specimens were either not given or were less detailed than those used for the SLNs.…”
Section: Characteristics Of Included Studiesmentioning
confidence: 99%
See 1 more Smart Citation
“…In such cases, only the sensitivity and specificity results can be given for the combination of tests used rather than only blue dye or 99m Tc separately or only both used together in all patients. However, for the other 20 studies, 50,51,[53][54][55][56][57][58][59][60][61][63][64][65][68][69][70][71][72][73][74] detection rates per groin can be given for each test separately and both tests combined (see Table 7). It is noticeable that the histopathological techniques used for the full IFL specimens were either not given or were less detailed than those used for the SLNs.…”
Section: Characteristics Of Included Studiesmentioning
confidence: 99%
“…It is noticeable that the histopathological techniques used for the full IFL specimens were either not given or were less detailed than those used for the SLNs. Only De Cicco et al, 55 Johann et al 59 and Radziszewski et al 68 appeared to use the same techniques and very little detail is given in the first two. More details of index tests and reference standards used are given in Appendix 10.…”
Section: Characteristics Of Included Studiesmentioning
confidence: 99%
“…Lymphatic mapping with 99m technetium labelled colloidal albumin either alone or in combination with blue dye yields generally better detection rates (89-100%) than the use of blue dye alone (56-95%). 13,[23][24][25][26][27] Other authors have used solely radioactive tracer for mapping and achieved high detection rates between 98% and 100% (table 3). According to these data the addition use of blue dye appears to be of limited benefit.…”
Section: Limitations Of Our Findingsmentioning
confidence: 99%
“…This minimally invasive procedure allows selective ablation of the first draining tumor node, thereby permitting a less aggressive inguinal surgery. Published results are promising [12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%