2019
DOI: 10.1111/jcpe.13160
|View full text |Cite
|
Sign up to set email alerts
|

The accuracy of single‐tooth implants placed using fully digital‐guided surgery and freehand implant surgery

Abstract: The optimal three-dimensional (3D) implant position is a critically important factor for the long-term success of implant therapy, as it can ensure the proper design of the prosthesis. Optimal positioning of the implant can allow for favourable prosthetic outcomes, such as function, aesthetics, occlusion and implant loading patterns. Moreover, correct implant position is essential for ensuring a prosthesis design compatible with long-term maintenance and access for adequate oral hygiene (Assche et al., 2012; C… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
100
1
5

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 110 publications
(111 citation statements)
references
References 18 publications
5
100
1
5
Order By: Relevance
“…14,26 Data for the fully-digital workflow group were extracted from the two previously mentioned RCTs 14,26 which included information on both partially-and fully-digital workflows, and four additional studies which reported solely on fully-digital workflows. [15][16][17]27 3.3 | Results of the individual studies A total of 13 studies met the selection criteria for review ( Figure 2). This provided 669 implants in 325 patients.…”
Section: Study Characteristicsmentioning
confidence: 99%
See 1 more Smart Citation
“…14,26 Data for the fully-digital workflow group were extracted from the two previously mentioned RCTs 14,26 which included information on both partially-and fully-digital workflows, and four additional studies which reported solely on fully-digital workflows. [15][16][17]27 3.3 | Results of the individual studies A total of 13 studies met the selection criteria for review ( Figure 2). This provided 669 implants in 325 patients.…”
Section: Study Characteristicsmentioning
confidence: 99%
“…Angular deviation was reported in 12 out of 13 studies, including six RCTs 14,15,[23][24][25][26] and six prospective clinical studies. 12,16,17,21,22,27 The overall weighted mean angular deviation was 2.68 , with a 95% CI of 2.32 to 3.03 ( Figure 5).…”
Section: Angular Deviationmentioning
confidence: 99%
“…Because there was no control group in this study, we could not conclude that the computer-guided surgery was more accurate than the conventional implant surgery when placing one-piece ceramic implants. Although a few studies [ 23 , 24 ] have reported that the computer-guided surgery provided more accurate implant positioning than the conventional implant surgery, they are based on titanium implants, in which all surgical steps can be completely controlled through surgical templates. To the best of the authors’ knowledge, this study is the first to focus on the accuracy of computer-guided surgery involving a small-diameter one-piece ceramic implant.…”
Section: Discussionmentioning
confidence: 99%
“…Before implant surgery, the final position of the implants can be determined virtually using planning software and 3D radiograph images. The position of the inserted implants is of crucial importance for the final design of the anchored prosthesis and the long-term survival of the dentures [ 2 4 ]. In this context, template-guided implant surgery allows for the accurate placement of dental implants [ 2 , 3 ].…”
Section: Introductionmentioning
confidence: 99%
“…The position of the inserted implants is of crucial importance for the final design of the anchored prosthesis and the long-term survival of the dentures [ 2 4 ]. In this context, template-guided implant surgery allows for the accurate placement of dental implants [ 2 , 3 ]. A precise surgical template can be fabricated by merging the intraoral-scan data with the 3D radiographic data [ 5 7 ].…”
Section: Introductionmentioning
confidence: 99%