2020
DOI: 10.1186/s12941-020-00383-x
|View full text |Cite
|
Sign up to set email alerts
|

The accuracy of four commercial broth microdilution tests in the determination of the minimum inhibitory concentration of colistin

Abstract: Colistin is considered as one of the last-resort antibiotics and reliable antimicrobial susceptibility testing is therefore crucial. The reference standard for AST according to EUCAST and CLSI is broth microdilution (BMD). However, BMD is labor intensive to perform. Commercial antimicrobial susceptibility tests derived from BMD method are available. We investigated the performance of four different commercial tests: Sensititre™, SensiTest™ Colistin, Micronaut MIC Strip Colistin and UMIC Colistin using 70 clini… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
11
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 15 publications
1
11
0
1
Order By: Relevance
“…However, the limitation of this study is the low specificity, 53.4%. The low specificity of this assay can be explained by the several known challenges with polymyxin AST, especially with Enterobacter species and K. aerogenes ( 40 44 ). Broth microdilution is currently the “gold standard” for MIC determination since disc diffusion and Etest have higher false-susceptibility rates due to improper diffusion ( 43 ).…”
Section: Discussionmentioning
confidence: 99%
“…However, the limitation of this study is the low specificity, 53.4%. The low specificity of this assay can be explained by the several known challenges with polymyxin AST, especially with Enterobacter species and K. aerogenes ( 40 44 ). Broth microdilution is currently the “gold standard” for MIC determination since disc diffusion and Etest have higher false-susceptibility rates due to improper diffusion ( 43 ).…”
Section: Discussionmentioning
confidence: 99%
“…These differences may have been caused by methodological variations of the two AST methods, including antimicrobial compound preparation (dry powder in the Sensititre ® plate vs. wet solution in the broth breakpoint plate), inoculum preparation (overnight incubation onto blood agar plates vs. in the 96-well plate with MH broth), reaction volume (50 µL in each well of the Sensititre ® plate vs. 200 µL in each well of broth breakpoint ), reaction concentration (1.4 × 10 5 cfu/mL, estimated by McFarland standards vs. 1.5 × 10 6 cfu/mL, estimated by OD 600 reading), and interpretation of AMR results (Vizion TM Digital MIC Viewing System vs. OD600 reading). In early comparative studies, the Sensititre ® platform was compared to other susceptibility tests (MicroScan, Vitek2, E-test, and Micronaut strip) for their essential and categorical agreements with broth micro-dilution method [ 24 , 25 , 26 , 27 ]. The Sensititre ® method exhibited 97.1% essential agreement with the reference broth micro-dilution method in measuring Klebsiella pneumoniae resistance to polymyxins and 92.5% for colistin [ 26 ], and acceptable categorical agreements (>90%) in measuring colistin and polymyxin B resistance in Enterobacteriaceae [ 24 , 27 ].…”
Section: Discussionmentioning
confidence: 99%
“…In early comparative studies, the Sensititre ® platform was compared to other susceptibility tests (MicroScan, Vitek2, E-test, and Micronaut strip) for their essential and categorical agreements with broth micro-dilution method [ 24 , 25 , 26 , 27 ]. The Sensititre ® method exhibited 97.1% essential agreement with the reference broth micro-dilution method in measuring Klebsiella pneumoniae resistance to polymyxins and 92.5% for colistin [ 26 ], and acceptable categorical agreements (>90%) in measuring colistin and polymyxin B resistance in Enterobacteriaceae [ 24 , 27 ]. No major errors were found with the Sensititre ® system [ 25 ].…”
Section: Discussionmentioning
confidence: 99%
“…showing the correlation with reference methods; the essential agreement values can slightly differ between individual products [47][48].…”
Section: Assays For Broth Microdilution Colistin Susceptibility Testing Are Also Commercially Availablementioning
confidence: 91%