1987
DOI: 10.1016/0028-2243(87)90021-9
|View full text |Cite
|
Sign up to set email alerts
|

The accuracy of colposcopically directed biopsy in diagnosis of CIN

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
5
0
3

Year Published

1988
1988
2018
2018

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 21 publications
2
5
0
3
Order By: Relevance
“…One microinvasive carcinoma was missed, but the colposcopy was performed 6 weeks after delivery. The overall accuracy rate in our study was comparable to the 62 to 96% in the literature review published by Helmerhorst et al in 1987. In the present series the frequency of complete excision by conization was 94%. Compared with the figures given in the literature (60% to 94%) our results are excellent (Ahlgren et al 1975, Kolstad et al 1976, Burghardt et al 1980, Larsson 1983.…”
Section: Discussionsupporting
confidence: 92%
“…One microinvasive carcinoma was missed, but the colposcopy was performed 6 weeks after delivery. The overall accuracy rate in our study was comparable to the 62 to 96% in the literature review published by Helmerhorst et al in 1987. In the present series the frequency of complete excision by conization was 94%. Compared with the figures given in the literature (60% to 94%) our results are excellent (Ahlgren et al 1975, Kolstad et al 1976, Burghardt et al 1980, Larsson 1983.…”
Section: Discussionsupporting
confidence: 92%
“…In our series there are significant association of cervical precancers and cancer cases with poor socioeconomic conditions, early age at marriage and high parity. These sociodemographic profile is comparable with other studies 13,14 During the last decade there has been an increasing interest in the use of colposcope 15 . Colposcopy guided biopsy is described as the reference investigation or "gold standard" for the diagnosis of cervical precancer 16 .…”
Section: Resultssupporting
confidence: 75%
“…The reported sensitivities ranged from 55.9 to 100.0%. Studies that reported 100% sensitivity were retrospective in design 25,28,29 . Three out of four of the prospective studies with immediate excision biopsies were at the upper end of the specificity spectrum 67.5–79.4%, but showed lower sensitivity (55.9–82.8%) 8,35,53 .…”
Section: Resultsmentioning
confidence: 99%
“…Studies that reported 100% sensitivity were retrospective in design. 25,28,29 Three out of four of the prospective studies with immediate excision biopsies were at the upper end of the specificity spectrum 67.5-79.4%, but showed lower sensitivity (55.9-82.8%). 8,35,53 Four studies reported specificities of <5% but sensitivities between 87.4 and 99.2%.…”
Section: Accuracy Of Punch Biopsiesmentioning
confidence: 96%