The accuracy of a novel 3D digital evaluation method of intraoral fitness for removable partial dentures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 26 publications
0
2
0
Order By: Relevance
“…The the silicone replica of the gap may be sectioned afterwards and its thickness directly revealing the gap was measured with stereomicroscope, digital microscope, electronic calipers or profile projector [ 18 , 35 , 45 , 46 ]. However, Yoon et al reported that the number of measuring points have effect on the average thickness of the silicon replicas, and that the accuracy of silicone film method was not sufficiently reliable [ 47 ]. In contrast, three-dimensional surface-matching can be used to assess the fit accuracy of RPDs more comprehensively and effectively than silicone film method [ 47 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The the silicone replica of the gap may be sectioned afterwards and its thickness directly revealing the gap was measured with stereomicroscope, digital microscope, electronic calipers or profile projector [ 18 , 35 , 45 , 46 ]. However, Yoon et al reported that the number of measuring points have effect on the average thickness of the silicon replicas, and that the accuracy of silicone film method was not sufficiently reliable [ 47 ]. In contrast, three-dimensional surface-matching can be used to assess the fit accuracy of RPDs more comprehensively and effectively than silicone film method [ 47 ].…”
Section: Discussionmentioning
confidence: 99%
“…However, Yoon et al reported that the number of measuring points have effect on the average thickness of the silicon replicas, and that the accuracy of silicone film method was not sufficiently reliable [ 47 ]. In contrast, three-dimensional surface-matching can be used to assess the fit accuracy of RPDs more comprehensively and effectively than silicone film method [ 47 ]. Consequently, for silicone film method, the adequate force applied during the setting time, the type of silicone replica, as well as the number and site of measuring points need to be clarified, which is necessary to insure the reliability and reproducibility of the outcomes of individual studies in the future.…”
Section: Discussionmentioning
confidence: 99%
“…Accurate measurement and fast analysis were done. (12) The use of unpolymerized polymers for printing the castable patterns may be responsible for these outcomes. Polymerization shrinkage during the 3D printing process is theoretically possible since the patterns are not fully polymerized.…”
Section: Ii) 2d and 3d Comparison Between Conventionalmentioning
confidence: 99%