The accuracy and reliability of 3D printed aortic templates: a comprehensive three-dimensional analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 40 publications
0
12
0
Order By: Relevance
“…However, to the best of our knowledge, at the moment, there are no research reports on the efficacy of sterilization of these aortic 3D templates. Although three-dimensional printed aortic templates have been demonstrated to be quite accurate [ 5 ], the effect of sterilization on the 3D-printed aortic template’s geometry is also unclear, and it might be fatal if altered.…”
Section: Introductionmentioning
confidence: 99%
“…However, to the best of our knowledge, at the moment, there are no research reports on the efficacy of sterilization of these aortic 3D templates. Although three-dimensional printed aortic templates have been demonstrated to be quite accurate [ 5 ], the effect of sterilization on the 3D-printed aortic template’s geometry is also unclear, and it might be fatal if altered.…”
Section: Introductionmentioning
confidence: 99%
“…The selection between SLA and FDM technologies depends on the required material properties, the financial constraints, and the application-driven characteristics that are desired in the phantoms. 8 The present case study documents the application of a patient-specific SLA 3D-printed model, illustrating its utility in addressing the intricacies of aortic arch aneurysms characterized by complex neck anatomy and landing zones. The focus is to elucidate how the use of SLA 3D-printed phantoms can contribute to the decision-making process and the finetuning of device delivery according to the unique anatomical features of every patient.…”
Section: Introductionmentioning
confidence: 92%
“…The selection between SLA and FDM technologies depends on the required material properties, the financial constraints, and the application-driven characteristics that are desired in the phantoms. 8…”
Section: Introductionmentioning
confidence: 99%
“…The aortic templates obtained in this way are characterized by excellent accuracy compared with the initial CT scan. 13 Marking fenestration sites is done by applying the template to the stent-graft and then rotating and moving it until a position is found that does not interfere with the stent struts. 10 The subsequent steps of stent-graft modification do not differ from the standard method.…”
Section: Introductionmentioning