2007
DOI: 10.1109/mpae.2007.329194
|View full text |Cite
|
Sign up to set email alerts
|

The ABCs of HVDC transmission technologies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
234
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 602 publications
(262 citation statements)
references
References 1 publication
1
234
0
Order By: Relevance
“…The low harmonic content of currents and voltages in the VSC HVDC systems allow these filters to be small and simple [34].  Back-to-back HVDC systems [17,33]  Bipolar HVDC systems (bipole, bipole with metallic return, bipole with series-connected converters) [17,33,55]  Multi-terminal HVDC systems [17,33,55] Figure 3: HVDC system topologies…”
Section: Capacitors and Filtersmentioning
confidence: 99%
See 2 more Smart Citations
“…The low harmonic content of currents and voltages in the VSC HVDC systems allow these filters to be small and simple [34].  Back-to-back HVDC systems [17,33]  Bipolar HVDC systems (bipole, bipole with metallic return, bipole with series-connected converters) [17,33,55]  Multi-terminal HVDC systems [17,33,55] Figure 3: HVDC system topologies…”
Section: Capacitors and Filtersmentioning
confidence: 99%
“…This implies the capability of power control, since the active power is regulated by changing the phase of the AC converter voltage, whereas the reactive power is controlled by adjusting the magnitude of the AC converter voltage [33,34]. The active power control loop can be set to regulate the active power flow according to the DC voltage, the frequency variation or an active power reference value.…”
Section: Main Controllersmentioning
confidence: 99%
See 1 more Smart Citation
“…In bipolar HVDC schemes, the midpoint of the dc capacitors is usually grounded to provide a reference voltage to the pole voltages [17], [18]. The midpoint is grounded either via a low-ohmic connection or through a reactor depending on the requirement, whether the bipole has to be able to be operated in monopolar mode or not [19].…”
Section: Transients In Hvdc Networkmentioning
confidence: 99%
“…The reactive power control loop can be set to control either the reactive power or the ac-side voltage. Either of these two modes can be selected independently at either end of the dc link [30]. Figure 2.1 shows a simple single line diagram of the basic components of a VSC-HVdc system.…”
Section: List Of Publicationsmentioning
confidence: 99%