The 1995 IAEA intercomparison of γ-ray spectrum analysis software

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0
2

Year Published

1999
1999
2012
2012

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(13 citation statements)
references
References 9 publications
0
11
0
2
Order By: Relevance
“…6 shows the 2 values computed from the reference uncertainties only ("reference") and from the combination of both the reference and calculated uncertainties of the program ("reported") for the small peaks on a low background and all of the peaks. The reduced χ 2 values were calculated by using the same procedures as in the IAEA 1995 test [18]. The reference uncertainties denote those of peak areas which were contained in the reference list used for the IAEA 2002 test [1], and the reported uncertainties denote those of peak areas which were determined by using HyperGam.…”
Section: Analysis Of Small Peaks and Peak Areasmentioning
confidence: 99%
“…6 shows the 2 values computed from the reference uncertainties only ("reference") and from the combination of both the reference and calculated uncertainties of the program ("reported") for the small peaks on a low background and all of the peaks. The reduced χ 2 values were calculated by using the same procedures as in the IAEA 1995 test [18]. The reference uncertainties denote those of peak areas which were contained in the reference list used for the IAEA 2002 test [1], and the reported uncertainties denote those of peak areas which were determined by using HyperGam.…”
Section: Analysis Of Small Peaks and Peak Areasmentioning
confidence: 99%
“…Peak search thresholds were left at the default value or set to the value advised in the manual of the program. The reported peak areas were compared with the reference peak areas [10] in terms of z-scores and reduced w 2 -values, using the same procedures as in the 1995 IAEA intercomparison [2]. Special attention was paid to the small peaks on low background, these being the most important kind in low-level g-ray spectrometry.…”
Section: Peak Area Determinationmentioning
confidence: 99%
“…The results, including the diskette with the test spectra, were published as an IAEA TECDOC-1011 ''Intercomparison of g-ray analysis software packages''. In addition, two articles giving brief explanations of the test spectra, intercomparison method used and the results were published in this journal [1,2].…”
Section: Introductionmentioning
confidence: 99%
“…Measurements were performed on the HPGe detector Amanda which has a relative efficiency of 38.2% and a resolution of 1.77 keV (both at 1332.5 keV) and which is further equipped with a 'dual option' LFC (loss free counting system) ND599. All irradiations and measurements were done in quadruplicate and the obtained spectra were deconvoluted with Hypermet-PC (version 5.0) [11] which was proven to be one of the best fitting programs [12].…”
Section: Remeasurement Of Ko-factors For Individual Gamma-linesmentioning
confidence: 99%