2001
DOI: 10.2165/00007256-200131070-00004
|View full text |Cite|
|
Sign up to set email alerts
|

Tests of Cycling Performance

Abstract: Performance tests are an integral component of assessment for competitive cyclists in practical and research settings. Cycle ergometry is the basis of most of these tests. Most cycle ergometers are stationary devices that measure power while a cyclist pedals against sliding friction (e.g. Monark), electromagnetic braking (e.g. Lode), or air resistance (e.g. Kingcycle). Mobile ergometers (e.g. SRM cranks) allow measurement of power through the drive train of the cyclist's own bike in real or simulated competiti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

4
80
2

Year Published

2002
2002
2018
2018

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 142 publications
(86 citation statements)
references
References 17 publications
4
80
2
Order By: Relevance
“…Participants were instructed to complete the 25 km in the fastest time possible, with only ‘distance completed’ provided as feedback. The reliability of cycling time trials over similar distances have been reported to be good, typically eliciting a random error of between 2% and 3% 19. During the time trial, power output was recorded at a frequency of 1 Hz, and heart rate was measured using a Polar 810i heart rate monitor (Polar Electro Oy, Finland) at 5 s intervals, with 1 km average values reported.…”
Section: Methodsmentioning
confidence: 99%
“…Participants were instructed to complete the 25 km in the fastest time possible, with only ‘distance completed’ provided as feedback. The reliability of cycling time trials over similar distances have been reported to be good, typically eliciting a random error of between 2% and 3% 19. During the time trial, power output was recorded at a frequency of 1 Hz, and heart rate was measured using a Polar 810i heart rate monitor (Polar Electro Oy, Finland) at 5 s intervals, with 1 km average values reported.…”
Section: Methodsmentioning
confidence: 99%
“…Paton and Hopkins12 reported a systematic error of 6% to 12% at high intensity in electromagnetic ergometers, whereas Clark and Grennleaf23 observed an overestimation of 3% going up to 50% at high workload after 1 hour of work. Consequently, Lifecycle underestimates the standard Vo 2 of −10% to −15% at 100 to 300 W. Thus, an overestimation of the PO also results in a relatively low Vo 2 at any displayed PO or a high mechanical efficiency value when Vo 2 is directly measured.…”
Section: Discussionmentioning
confidence: 98%
“…Recently, the Monark 814e was still used to validate the performance and metabolic measures of Lode Excalibur Sport ergometer during a Wingate Anaerobic Test 11. The PowerTap device PO is approximately 8% higher than the one displayed by the SRM crank set 12. These results differ from the study of Bertucci et al 13 showing that PowerTap device is a valid and reliable mobile power meter during submaximal intensities when compared with the scientific SRM model.…”
mentioning
confidence: 91%
“…Indeed, this has been suggested as a critical factor for producing reliable results, 6 and ergometers that allow attachment of an individual's own bicycle have been shown to produce more reliable results than stand-alone ergometers. 4 Geometry and lower-limb kinematics that most closely replicate a cyclist's position on his or her own bike are associated with improved economy, 15 and for that reason an ergometer that closely reflects the feel of cycling may provide a superior means of assessing exercise performance when compared with ergometers that allow minimal adjustments.…”
Section: Discussionmentioning
confidence: 99%
“…In cycling, the systematic error may relate to the inability of an ergometer to accurately measure power output. 6 The Wattbike cycle ergometer is currently used in numerous sporting facilities and university laboratories to assess and monitor cycling performance. To date, only a limited number of studies have investigated the accuracy and reproducibility of the ergometer.…”
mentioning
confidence: 99%