2020
DOI: 10.3390/ma13092118
|View full text |Cite
|
Sign up to set email alerts
|

Tests of Concrete Strength across the Thickness of Industrial Floor Using the Ultrasonic Method with Exponential Spot Heads

Abstract: The accepted methods for testing concrete are not favorable for determining its heterogeneity. The interpretation of the compressive strength result as a product of destructive force and cross-section area is burdened with significant understatements. It is assumed erroneously that this is the lowest value of strength at the height of the tested sample. The top layer of concrete floors often crumble, and the strength tested using sclerometric methods does not confirm the concrete class determined using control… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
19
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 21 publications
(20 citation statements)
references
References 23 publications
1
19
0
Order By: Relevance
“…Using a mutation scanning pipeline in PyRosetta 59,60 we predicted the impact on binding affinity for each variant (Fig 1.d). The three population variants predicted to have the largest impact on S-ACE2 binding affinity-ACE2_E37K (ΔΔG=1.50), ACE2_M82I (ΔΔG=2.95), and ACE2_G326E (ΔΔG=5.74)-were all consistent with previous experimental screens which identified them as putative protective variants exhibiting decreased binding of ACE2 to S 61,62 .…”
Section: Enrichment Of Divergence Between Sars-cov and Sars-cov-2 At supporting
confidence: 86%
“…Using a mutation scanning pipeline in PyRosetta 59,60 we predicted the impact on binding affinity for each variant (Fig 1.d). The three population variants predicted to have the largest impact on S-ACE2 binding affinity-ACE2_E37K (ΔΔG=1.50), ACE2_M82I (ΔΔG=2.95), and ACE2_G326E (ΔΔG=5.74)-were all consistent with previous experimental screens which identified them as putative protective variants exhibiting decreased binding of ACE2 to S 61,62 .…”
Section: Enrichment Of Divergence Between Sars-cov and Sars-cov-2 At supporting
confidence: 86%
“…The purpose of the completed research project was to verify previous test results [ 8 ] indicate a lack of variability in the compressive strength of concrete on the thickness of tested elements. The results in the publication [ 8 ] debunked the results of previous studies [ 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 ], in which it was proven that the differentiation of the compressive strength of concrete occurs on the thickness of horizontally formed slabs.…”
Section: Discussionmentioning
confidence: 99%
“…In studies [ 4 , 5 , 6 , 7 , 8 , 9 , 10 , 11 , 12 , 13 , 14 , 15 , 16 ], it was proven that the differentiation of the compressive strength of concrete occurs across the thickness of thin horizontally formed slabs. The opinions of various researchers concern the size of the difference in the compressive strength between the various levels at which it is tested.…”
Section: Introductionmentioning
confidence: 99%
“…This results in the low compressive strength of the concrete in the upper part of its cross-section (about 30–40% of the designed strength of concrete). According to research [ 2 ], the heterogeneity of concrete also causes the delamination and loosening of its top layer, which contributes to its damage. Fibers can improve the homogeneity of the concrete.…”
Section: Introductionmentioning
confidence: 99%