Tests and Performance Analysis of 2G HTS Transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 5 publications
0
10
0
Order By: Relevance
“…Such superconducting windings cause that the switching current of the superconducting transformer reaches higher values and longer decay times compared to conventional transformers. Superconducting transformers Four transformers were tested: three 8.5 kVA ones [4] and one 13.8 kVA one [5]. The 8.5 kVA transformers had the same coil core RZC-70/230-70.…”
Section: Effect Of Superconductor Resistancementioning
confidence: 99%
“…Such superconducting windings cause that the switching current of the superconducting transformer reaches higher values and longer decay times compared to conventional transformers. Superconducting transformers Four transformers were tested: three 8.5 kVA ones [4] and one 13.8 kVA one [5]. The 8.5 kVA transformers had the same coil core RZC-70/230-70.…”
Section: Effect Of Superconductor Resistancementioning
confidence: 99%
“…A properly designed superconducting transformer in addition to electric energy conversion can simultaneously play the role of a fault current limiter [11]. In the case of current of a magnitude exceeding the critical value for the winding, the superconducting material will switch to a resistive state.…”
Section: Superconducting Transformersmentioning
confidence: 99%
“…In Laboratory of Superconducting Technologies in Lublin there was designed and built the single-phase model of a 8.8 kVA HTS transformer [6], presented in cig. 4.…”
Section: Design Of the Hts Transformermentioning
confidence: 99%
“…Experimental studies included the determination of short-circuit characteristics and short-circuit tests, using the parameters of the HTS tape, in order to verify the ability of the superconducting winding to limit the short-circuit current [6,7]. The examinations were carried out for a HTS transformer with two values of air gap width, compared with a conventional (copper) transformer of the same nominal power.…”
Section: Experimental Examinationmentioning
confidence: 99%