2010
DOI: 10.1134/s0020441210010033
|View full text |Cite
|
Sign up to set email alerts
|

Testing the engineering sample of the NUCLEON setup on a pion beam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
7
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 1 publication
0
7
0
Order By: Relevance
“…Details on the KLEM method and its ground tests can be found in these articles: G. L. Bashindzhagyan et al (2005); A. Turundaevskiy et al (2005); A. G. Voronin et al (2007); V. L. Bulatov et al (2010). The analysis method and preliminary analysis results of both the calorimeter and the KLEM can be found in E. Atkin et al (2017.1).…”
Section: The Nucleon Observatorymentioning
confidence: 99%
“…Details on the KLEM method and its ground tests can be found in these articles: G. L. Bashindzhagyan et al (2005); A. Turundaevskiy et al (2005); A. G. Voronin et al (2007); V. L. Bulatov et al (2010). The analysis method and preliminary analysis results of both the calorimeter and the KLEM can be found in E. Atkin et al (2017.1).…”
Section: The Nucleon Observatorymentioning
confidence: 99%
“…2) are four planes of the charge measurement system, a carbon target, six planes of the energy measurement system using the KLEM method (KLEM system tracker), three double-layer planes of the scintillator trigger system, and a small aperture ionization calorimeter (25 × 25 cm 2 ). Details of the detector design are provided in the articles [33,34,35,36,37]. On December 28, 2014, the NUCLEON detector was launched into a sun-synchronous orbit.…”
mentioning
confidence: 99%
“…It is expected that the systematic errors of the data are mainly related to uncertainties of the event trigger operation and they are estimated to be approximately 25% in absolute intensity and ±0.06 in the common spectral index of the spectra. The systematics related to energy determination by the both methods were tested in CERN beam tests experiments [36] and expected to be ∼5%. The IC method and the KLEM method of energy measurement are in fact two different experiments with different physics of generation of the trigger, jointed in one experimental setup.…”
mentioning
confidence: 99%
“…The NUCLEON device [11][12][13][14][15][16] was designed and produced by the collaboration of SINP MSU (the main investigator), JINR (Dubna) and a number of other Russian scientific and industrial centres. Currently, it is placed on board the RESURS-P №2 satellite.…”
Section: The Nucleon Designmentioning
confidence: 99%