2013
DOI: 10.1134/s1063780x13040090
|View full text |Cite
|
Sign up to set email alerts
|

Testing of the method for water microleakage detection from OH hydroxyl spectral lines at the L-2M stellarator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…In last decade, several versions of emission spectroscopy techniques concerned with this problem were elaborated. A brief review of these approaches is presented in [1][2][3][4][5][6]. The best sensitivity of the leak monitoring at the level of 10 −7 Pa • m 3 • s −1 (10 −7 Pa • m 3 • s −1 = 10 −9 mbar • m 3 • s −1 = 10 −6 mbar • l • s −1 = 10 −7 W or ~10 13 molecules s −1 ) was demonstrated by means of a combination of the probe and absolute optical measurements or by optical actinometry techniques, whereby the sensitivity specified by project ITER [7], which is presently under construction, was attained.…”
Section: Introductionmentioning
confidence: 99%
“…In last decade, several versions of emission spectroscopy techniques concerned with this problem were elaborated. A brief review of these approaches is presented in [1][2][3][4][5][6]. The best sensitivity of the leak monitoring at the level of 10 −7 Pa • m 3 • s −1 (10 −7 Pa • m 3 • s −1 = 10 −9 mbar • m 3 • s −1 = 10 −6 mbar • l • s −1 = 10 −7 W or ~10 13 molecules s −1 ) was demonstrated by means of a combination of the probe and absolute optical measurements or by optical actinometry techniques, whereby the sensitivity specified by project ITER [7], which is presently under construction, was attained.…”
Section: Introductionmentioning
confidence: 99%
“…A complex of spectroscopic studies was carried out on an L-2M stellarator (the major radius of 1 m, the minor radius of 0.115 m) [161][162][163]. There were also carried out measurements on the OH luminescence according to the method of [160], which confirmed the sensitivity of 10 -5 Pa m 3 s -1 [162,163].…”
Section: Preceding Ongoing and Required Studiesmentioning
confidence: 90%
“…A complex of spectroscopic studies was carried out on an L-2M stellarator (the major radius of 1 m, the minor radius of 0.115 m) [161][162][163]. There were also carried out measurements on the OH luminescence according to the method of [160], which confirmed the sensitivity of 10 -5 Pa m 3 s -1 [162,163]. The idea [153,157] on the use of Xe as a marker [161,163] was tested in parallel but in this case the marker was detected from the emission spectrum.…”
Section: Preceding Ongoing and Required Studiesmentioning
confidence: 99%
“…In addition to gas bottles, a thermochemical water vapor source (TWVS) based on the thermal decomposition reaction Ca(OH) 2 ↔CaO+H 2 O, similar to that described in [25,26] is connected to the deposition chamber. This allows the study of interaction of deposited films with water vapor under controlled conditions.…”
Section: Vacuum Systemmentioning
confidence: 99%