1999
DOI: 10.2172/9380
|View full text |Cite
|
Sign up to set email alerts
|

Testing of In-Line Slurry Monitors and Pulsair Mixers with Radioactive Slurries

Abstract: Web site http:llw.ntis.govlordering.htm Reports are available to U.S. Department of Energy (DOE) employees, DOE contractors, Energy Technology Data Exchange (El_DE) representatives, and International Nuclear Information System (INIS) representatives from the following source. Office of Scientific and Technical Information P.O. BOX 62 Oak Ridge, TN 37831

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2000
2000
2002
2002

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(23 citation statements)
references
References 0 publications
0
23
0
Order By: Relevance
“…Criteria for transfer of waste slurries through the ICPL require the concentration of suspended solids to be <5 wt % and the maximum particle size to be 100 µm (Hylton and Bayne, 1999). The SMTL was designed to provide real-time monitoring of the radioactive slurry conditions before and during waste transfers to the MVST.…”
Section: Smtlmentioning
confidence: 99%
“…Criteria for transfer of waste slurries through the ICPL require the concentration of suspended solids to be <5 wt % and the maximum particle size to be 100 µm (Hylton and Bayne, 1999). The SMTL was designed to provide real-time monitoring of the radioactive slurry conditions before and during waste transfers to the MVST.…”
Section: Smtlmentioning
confidence: 99%
“…Ultrasonic devices for measuring both density and fluid velocity within a pipe exist (Hylton and Bayne 1999;Greenwood and Bamberger 2000), but at its current stage of development, the technology does not appear to provide the accuracy or reliability that is obtained with commercially available Coriolis and EM meters. No further discussion of ultrasonic technologies will be presented.…”
Section: Instrumentationmentioning
confidence: 99%
“…The discussion 3.12 and results presented in this section are taken from the report prepared by Hylton and Bayne (1999) on the testing of in-line slurry monitoring devices at ORNL. A schematic of the Tank W-9 and the SMTS system is shown in Figure 3.12.…”
Section: Qualification Testing At Ornlmentioning
confidence: 99%
“…A schematic of the Tank W-9 and the SMTS system is shown in Figure 3.12. A detiiled description of the SMTS also is available in Hylton and Bayne (1999).…”
Section: Qualification Testing At Ornlmentioning
confidence: 99%
See 1 more Smart Citation