2019 IEEE 10th International Workshop on Applied Measurements for Power Systems (AMPS) 2019
DOI: 10.1109/amps.2019.8897781
|View full text |Cite
|
Sign up to set email alerts
|

Testing of Electrical Energy Meters in Off-Nominal Frequency Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
20
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(21 citation statements)
references
References 21 publications
1
20
0
Order By: Relevance
“…where all the parameters with index h are correlated to a specific harmonic order h. An additional measurement data set is presented, as a conclusion of the first part of practical analysis. The following measurement results are recorded during an examination procedure performed on 4 instruments for active power/energy, in order for a general acceptance of the error function, presented in (16), to be adopted. The 4 active power/energy instruments used in the concrete procedure as a UUT are: − Landys+Gyr ZMD405CT44.2407 [23], i.e.…”
Section: Case Studymentioning
confidence: 99%
See 3 more Smart Citations
“…where all the parameters with index h are correlated to a specific harmonic order h. An additional measurement data set is presented, as a conclusion of the first part of practical analysis. The following measurement results are recorded during an examination procedure performed on 4 instruments for active power/energy, in order for a general acceptance of the error function, presented in (16), to be adopted. The 4 active power/energy instruments used in the concrete procedure as a UUT are: − Landys+Gyr ZMD405CT44.2407 [23], i.e.…”
Section: Case Studymentioning
confidence: 99%
“…The difference between the error functions' intensity is due to the fact that, every measuring device is tested with voltages and currents with different amplitudes. According to (16) the errors are proportional to the RMS of the harmonic components, which are, according to (5), proportional to the fundamental voltages and currents. An error function with the greatest amplitude is recorded when the examination is performed on Landys+Gyr ZMD310CT44.0000, because this device is tested with the highest voltage and current signals, U = 220 V and I = 20 A, respectively.…”
Section: Case Studymentioning
confidence: 99%
See 2 more Smart Citations
“…Two asset management systems have been developed in [10,11] and the integration of electric vehicles and storage systems into smart grids has been detailed in [12] and [13], respectively. Lastly, the performance of energy meters under non-rated conditions, hence affected by PQ issues, are studied in [14][15][16][17][18][19].…”
Section: Introductionmentioning
confidence: 99%