2022 20th International Conference on Harmonics &Amp; Quality of Power (ICHQP) 2022
DOI: 10.1109/ichqp53011.2022.9808496
|View full text |Cite
|
Sign up to set email alerts
|

Testing of DC Electricity Meters with Broadband Conducted Electromagnetic Disturbances

Abstract: The shift towards more renewable energy sources and sustainable technologies has increased the interest in low-voltage DC grids. However, the definition of power quality issues in DC grids and related measurement techniques are still in their infancy. Consequently, standardization of DC electricity meter testing is not yet fully covering immunity to DC-grid-specific disturbances. Therefore, a new arbitrary-waveform testbed has been developed for testing of DC electricity meters in the presence of broadband dis… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 19 publications
0
5
0
Order By: Relevance
“…The standardization of DC electricity meter testing does not fully address immunity to DC-specific disturbances. In this context, an arbitrary waveform testbed was created in [83] for testing DC electricity meters. This testbed can assess meters in the presence of broadband disturbance signals with frequency components up to 150 kHz.…”
Section: Feasibility Studies and Potential Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…The standardization of DC electricity meter testing does not fully address immunity to DC-specific disturbances. In this context, an arbitrary waveform testbed was created in [83] for testing DC electricity meters. This testbed can assess meters in the presence of broadband disturbance signals with frequency components up to 150 kHz.…”
Section: Feasibility Studies and Potential Applicationsmentioning
confidence: 99%
“…Reference [211] demonstrated the real-time operation and harmonic analysis of DC networks, aiming to comprehend the influence of power quality on grid performance. The assessment of DC meters for electromagnetic disturbances was investigated in [83] to guarantee the precise measurement and monitoring of power quality in DC networks.…”
Section: Power Qualitymentioning
confidence: 99%
“…The need for measurements to underpin new definitions of DC PQ is addressed in the European metrology project "20NRM03 DC Grids" [14] by measuring and analyzing the distortions occurring in LV DC microgrids and developing reference systems for the calibration of DC power meters [15] and DC PQ analyzers, and for testing DC equipment such as DC electricity meters in the presence of well-defined distortions [16]. The first measurement campaigns have been executed already in LV DC microgrids in Malaga Smart City in Spain, with micro wind turbines and PV panels at a voltage level of 48 V [17], the Green Village in Delft, the Netherlands, with LED streetlights and PV panels and operated at 350 V [18], and three different public EV charging stations in Germany [19].…”
Section: Introductionmentioning
confidence: 99%
“…Measurement campaigns have been planned for existing LV DC grid trials, such as in Malaga Smart City [27]. Furthermore, initial reference systems for DC power [28] and electricity meter testing in the presence of AC distortions [29] have been developed.…”
Section: Introductionmentioning
confidence: 99%