Testing and validation of wide‐area control of STATCOM using real‐time digital simulator with hybrid HIL–SIL configuration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 23 publications
(26 reference statements)
0
3
0
Order By: Relevance
“…The CHIL tests allowed the efficient tuning of the SVC controller, as well as effective fault tracing. A wide-area control of a STATCOM using a hybrid CHIL and software-in-the loop configuration was validated in [107]. The transient stability enhancement using a wide-area controlled SVC was investigated in a CHIL configuration [54].…”
Section: Hardware In the Loop Testing Of Factsmentioning
confidence: 99%
“…The CHIL tests allowed the efficient tuning of the SVC controller, as well as effective fault tracing. A wide-area control of a STATCOM using a hybrid CHIL and software-in-the loop configuration was validated in [107]. The transient stability enhancement using a wide-area controlled SVC was investigated in a CHIL configuration [54].…”
Section: Hardware In the Loop Testing Of Factsmentioning
confidence: 99%
“…One successful method for thorough testing requires a laboratory testbed consisting communication-enabled "realtime-simulator" which may be coupled with hardware-inloop (HIL), software-in-loop (SIL), power HIL (PHIL), and control HIL (CHIL) setup [11][12][13][14][15]. In [15], a synchrophasorbased voltage stability monitoring application was tested with (1) positive-sequence based (PSB) simulations, (2) PMU data from real-time-HIL, and (3) PMU data from a real Nordic grid transmission system, sequentially.…”
Section: Introductionmentioning
confidence: 99%
“…However, the problems related to the selection of optimal control loop are not addressed here. The use of PMU data for wide-area control of static synchronous compensator is discussed in [18], but the effect of mutual coupling during mode estimation and optimal signal selection is not represented. A power system model using MIMO identification based on auto-regressive moving average exogenous methodology is developed in [19], but an optimal method for signal selection is not addressed.…”
Section: Introductionmentioning
confidence: 99%