Clinical Cardiac Pacing, Defibrillation, and Resynchronization Therapy 2007
DOI: 10.1016/b978-1-4160-2536-8.50022-4
|View full text |Cite
|
Sign up to set email alerts
|

Testing and Programming of Implantable Defibrillator Functions at Implantation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
11
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 245 publications
0
11
0
Order By: Relevance
“…36 Reasons for such ICD-unresponsive SCD may be patient or device related, including refractory electrical storm, asystole, pulseless electrical activity or technical defects of the implanted device and leads or potentially elevated defibrillation thresholds (DFTs). 37 While there are several reports on changes of DFT by antiarrhythmic drugs in the literature (mostly historical studies and case reports from the 1980s and 1990s), there are few recent data regarding pacing threshold.…”
Section: Potential Influences On Pacing and Defibrillation Thresholdsmentioning
confidence: 99%
“…36 Reasons for such ICD-unresponsive SCD may be patient or device related, including refractory electrical storm, asystole, pulseless electrical activity or technical defects of the implanted device and leads or potentially elevated defibrillation thresholds (DFTs). 37 While there are several reports on changes of DFT by antiarrhythmic drugs in the literature (mostly historical studies and case reports from the 1980s and 1990s), there are few recent data regarding pacing threshold.…”
Section: Potential Influences On Pacing and Defibrillation Thresholdsmentioning
confidence: 99%
“…1 These unsettled issues include the optimal defibrillation lead configuration, need for waveform optimization at implantation, hemodynamic sequelae of ICD testing, and the need for yearly ICD testing to confirm response to ventricular fibrillation among others. Probably no aspect of ICD therapy is more unsettled than the effects of antiarrhythmics and other drugs on the DFT.…”
Section: Article P 104mentioning
confidence: 99%
“…Despite 20 years of clinical use, however, there exist many unresolved issues in ICD therapy. 1 Even the most fundamental aspect of ICD implantation, defibrillation threshold (DFT) testing, is not standardized. Determining a DFT is fundamentally different from determining a pacing threshold.…”
mentioning
confidence: 99%