2010
DOI: 10.1007/s10762-010-9650-z
|View full text |Cite
|
Sign up to set email alerts
|

Terahertz and Millimetre Wave Imaging with a Broadband Josephson Detector Working above 77 K

Abstract: A high-T c superconducting (HTS) broadband Josephson detector has been developed and applied to millimetre wave (mm-wave) and terahertz (THz) imaging. The detector is based on a YBa 2 Cu 3 O 7-x (YBCO) step-edge Josephson junction, which is coupled to a thin-film log-periodic antenna, designed for operation at 200-600 GHz, and a hemispheric silicon lens. The junction parameters have been optimised to achieve a high I c R n value so that the detector responds well to the specified frequencies at liquid nitrogen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 19 publications
(24 citation statements)
references
References 30 publications
0
24
0
Order By: Relevance
“…J. C. Macfarlane (1) , J. Du (1) , and A. D. Hellicar (2) The heterodyne Josephson detector was fabricated using the CSIRO HTS YBa 2 Cu 3 O 7-x step-edge Josephson junction technology [5,6]. The operation principle and the fabrication details of the R-SQUID can be found in refs.…”
Section: Device Design and Fabricationmentioning
confidence: 99%
See 1 more Smart Citation
“…J. C. Macfarlane (1) , J. Du (1) , and A. D. Hellicar (2) The heterodyne Josephson detector was fabricated using the CSIRO HTS YBa 2 Cu 3 O 7-x step-edge Josephson junction technology [5,6]. The operation principle and the fabrication details of the R-SQUID can be found in refs.…”
Section: Device Design and Fabricationmentioning
confidence: 99%
“…MAGING at terahertz (THz) frequencies using hightemperature superconducting (HTS) step-edge Josephson detectors has been demonstrated recently [1,2]. The next step will be to achieve fast, real-time images, which will require progress to be made towards the use of multi-pixel detector arrays.…”
Section: Introductionmentioning
confidence: 99%
“…We have recently developed HTS step-edge Josephson junction THz detector and demonstrated THz imaging [18][19][20][21]. We optimize our step-edge Josephson junctions to achieve a maximum response to a signal frequency of 0.2 -0.6 THz for operating temperatures at 77 K [19][20][21].…”
Section: Hts Josephson Junction Thz Detector Array For Imagingmentioning
confidence: 99%
“…We optimize our step-edge Josephson junctions to achieve a maximum response to a signal frequency of 0.2 -0.6 THz for operating temperatures at 77 K [19][20][21]. However, a typical image size of 100 × 100 or 10,000 pixels takes ~ 20 minutes to obtain using a single HTS JJ detector.…”
Section: Hts Josephson Junction Thz Detector Array For Imagingmentioning
confidence: 99%
See 1 more Smart Citation