2004
DOI: 10.1016/j.biomaterials.2003.10.085
|View full text |Cite
|
Sign up to set email alerts
|

Temporary vascular occlusion with poloxamer 407

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
59
0
2

Year Published

2005
2005
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 78 publications
(62 citation statements)
references
References 11 publications
0
59
0
2
Order By: Relevance
“…However, this effect is likely to be insignificant because Poloxamer 407 has been used as a temporary vascular occlusion agent (20). Although small fragments of clots may detach and escape from the occluded vessels, especially the large veins (i.e., iliac veins and vena cava), they will accumulate in the lungs and be rapidly dissolved there (20). The rate of dissolution is much faster than that of large clots formed in the lung after a direct injection into the pulmonary artery because the rate of dissolution decreases with increasing size of clots.…”
Section: Resultsmentioning
confidence: 99%
“…However, this effect is likely to be insignificant because Poloxamer 407 has been used as a temporary vascular occlusion agent (20). Although small fragments of clots may detach and escape from the occluded vessels, especially the large veins (i.e., iliac veins and vena cava), they will accumulate in the lungs and be rapidly dissolved there (20). The rate of dissolution is much faster than that of large clots formed in the lung after a direct injection into the pulmonary artery because the rate of dissolution decreases with increasing size of clots.…”
Section: Resultsmentioning
confidence: 99%
“…As thermoreversibility allows PIB to be redissolved when the temperature falls, nontargeted embolization of PIB could be solved via redissolution, 30 and PIB might also be used for temporary embolization. 11 Because PNIPAM-based polymers have been shown to serve as vectors for drugs, proteins, and target genes, [6][7][8] PIB could also be modified to a "bioactive embolic agent" and thus widely applied in endovascular therapy.…”
Section: Inflammation Reactionsmentioning
confidence: 99%
“…10 Poloxamer, which has rapid reversible sol-gel transition behavior with a change of temperature, was reported as a temporary embolic material several years later. 11 Recently, a linear PNIPAM has been investigated in embolization of AVMs.…”
mentioning
confidence: 99%
“…Which seems indicates one of the important mechanisms of theophylline for its lipid lowering action. Poloxamer 407 is a hydrophilic, non-toxic, surface active agent with a low degree of toxicity that is being adapted for more specialized applications such as sealing permeabilized cell membranes and vascular occlusion procedures [5][6][7][8][9][10] . It has been shown to cause significant elevations in serum cholesterol and triglyceride levels after a single injection in rodent models 11 .…”
Section: Effect Of Theophylline On Biochemical Parameters In Poloxamementioning
confidence: 99%