Temporally separating Cherenkov radiation in a scintillator probe exposed to a pulsed X-ray beam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 11 publications
(12 citation statements)
references
References 20 publications
0
12
0
Order By: Relevance
“…The scintillator sensitive volume is a cylinder 0.5 mm long and 1 mm in diameter, giving a total sensitive volume of 0.39 mm3. Further details on the probe and optical fiber design can be found in previous works . Photodetection was performed with an RCA‐4526 photomultiplier tube (PMT).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The scintillator sensitive volume is a cylinder 0.5 mm long and 1 mm in diameter, giving a total sensitive volume of 0.39 mm3. Further details on the probe and optical fiber design can be found in previous works . Photodetection was performed with an RCA‐4526 photomultiplier tube (PMT).…”
Section: Methodsmentioning
confidence: 99%
“…The method we present here for Cherenkov removal is a more advanced development of the method described by Archer et al., where it was assumed that the beam intensity was constant for the duration of the pulse. To improve accuracy, we now instead assume the beam intensity closely matches the generated Cherenkov signal.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Thicknesses of 100 m and 50 m were used, defining sensitive volumes of 0.079 mm 3 and 0.039 mm 3 respectively. A 500 m probe was also fabricated using BC-444 scintillator (with a slower rise time than the BC-400) to test a method for temporal separation of Cherenkov light being developed [29].…”
Section: Photonic Dosimeter Designs and Testsmentioning
confidence: 99%
“…Pulse gating methods such as temporal filtration remove 99% of the Cerenkov radiation response at the expense of a 44% loss in scintillation response. Temporal analytic methods do not experience the loss in scintillation siganl inherent to temporal filtration, however accuracy in Cerenkov radiation estimation has not yet been sufficient to result in clinically acceptable dose discrepancies in scintillator dose measurement [7,8,9,10].…”
Section: Introductionmentioning
confidence: 99%