Temporal resolution improvement in cardiac CT using PICCS (TRI‐PICCS): Performance studies

Abstract: The TRI-PICCS method can be used to systematically improve temporal resolution for MDCT cardiac imaging by a factor of 2-2.3 and the performance of the TRI-PICCS method is insensitive to motion locations and motion orientations. The TRI-PICCS method enables a single-source MDCT scanner with 350 ms or faster gantry speed to scan patients with heart rates as high as 100 bpm.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
82
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 69 publications
(83 citation statements)
references
References 43 publications
1
82
0
Order By: Relevance
“…For the typical third generation architecture with a single X-ray tube and a single detector array positioned on a gantry and rotated jointly around the patient, the temporal resolution is approximately half of the gantry rotation time [15]. Modern single-tube systems have gantry rotation times of approximately 300 ms (270-350 ms), and a temporal resolution of approximately 150 ms. Temporal resolution can be improved using reconstruction techniques that work with limited projection data [16,17].…”
Section: Cardiac Ct Has Old Roots As Wellmentioning
confidence: 99%
“…For the typical third generation architecture with a single X-ray tube and a single detector array positioned on a gantry and rotated jointly around the patient, the temporal resolution is approximately half of the gantry rotation time [15]. Modern single-tube systems have gantry rotation times of approximately 300 ms (270-350 ms), and a temporal resolution of approximately 150 ms. Temporal resolution can be improved using reconstruction techniques that work with limited projection data [16,17].…”
Section: Cardiac Ct Has Old Roots As Wellmentioning
confidence: 99%
“…Note that there is no need to perform a full SVD in SVT λ (X), since only those singular values above the selected regularization parameter λ are needed as shown in Eq. (18). However, in the application presented in our paper, the difference between a full SVD and an economical SVD is negligible from computation load standpoint since we only have 3-5 time image columns and thus only 3-5 singular values.…”
Section: E Smart-recon: Objective Function and Numerical Implementmentioning
confidence: 99%
“…When a prior CT image of the same image object without limited-view artifacts is available for use in the reconstruction, limited-view artifacts can be mitigated using the PICCS algorithm 4,7,18 for an angular span greater than 180…”
Section: D Nuclear Norm Of the Prior Image Augmented Spatial-tempomentioning
confidence: 99%
See 2 more Smart Citations