2016
DOI: 10.1007/s10554-016-1011-0
|View full text |Cite
|
Sign up to set email alerts
|

Temporal averaging for analysis of four-dimensional whole-heart computed tomography perfusion of the myocardium: proof-of-concept study

Abstract: To assess the feasibility of four-dimensional (4D) whole-heart computed tomography perfusion (CTP) of the myocardium and the added value of temporal averaging of consecutive 3D datasets from different heartbeats for analysis. We included 30 patients with suspected or known coronary artery disease (CAD) who underwent 320-row coronary CT angiography (CTA) and myocardial CTP. Out of these, 15 patients underwent magnetic resonance myocardial perfusion imaging (MR MPI). All CTP examinations were initiated after 3 m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 43 publications
0
12
0
Order By: Relevance
“…For myocardial CT perfusion imaging, static imaging either with or without a vasodilator stressor (such as adenosine) is used, whereas dynamic (4D) imaging allows the quantification of MBF but requires multiple scans over time. Dynamic CT perfusion imaging might provide the greatest clinical value but challenges with this modality include increased radiation dose, motion artefacts and image quality limitations 140 . A meta-analysis showed higher sensitivity (0.85 versus 0.72) but lower specificity (0.81 versus 0.90) for dynamic compared with static CT perfusion imaging 141 .…”
Section: Key Points For Echocardiographymentioning
confidence: 99%
“…For myocardial CT perfusion imaging, static imaging either with or without a vasodilator stressor (such as adenosine) is used, whereas dynamic (4D) imaging allows the quantification of MBF but requires multiple scans over time. Dynamic CT perfusion imaging might provide the greatest clinical value but challenges with this modality include increased radiation dose, motion artefacts and image quality limitations 140 . A meta-analysis showed higher sensitivity (0.85 versus 0.72) but lower specificity (0.81 versus 0.90) for dynamic compared with static CT perfusion imaging 141 .…”
Section: Key Points For Echocardiographymentioning
confidence: 99%
“…A study conducted in 32 Asian patients [ 17 ] shows a good correlation of the myocardial blood flow and the coronary flow reserve determined by 4D CTP compared with the findings of positron emission tomography. We investigated additional objective (noise, SNR and CNR) and subjective image quality parameters [ 18 ], which have already been published in the main manuscript of our study. For 4D dynamic CTP, we chose a protocol aimed at acquiring 20 heart beats, which was not always possible in patients with low or high heart rate.…”
Section: Discussionmentioning
confidence: 99%
“…This is the contour sharpness sub-study of the prospective 4D CT perfusion pilot study [ 18 ]. A detailed description of in- and exclusion criteria, patient preparation and CT protocol has already been published with the main study.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Feger et al evaluated the feasibility of four-dimensional (4D) whole-heart computed tomography perfusion (CTP) of the myocardium and the added value of temporal averaging of consecutive 3D datasets from different heartbeats for analysis [84]. Out of 30 patients with suspected or known CAD who underwent 320-row coronary CT angiography (CTA) and myocardial CTP, 15 patients underwent magnetic resonance myocardial perfusion imaging (MR MPI).…”
Section: Computed Tomographymentioning
confidence: 99%