2018
DOI: 10.1016/j.yofte.2018.08.013
|View full text |Cite
|
Sign up to set email alerts
|

Temperature sensing characteristics of metal coated FBG during dynamic cooling process

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 30 publications
0
11
0
Order By: Relevance
“…Unlike PDMS, which is mostly used for temperature measurement, polyimide is mostly used for humidity measurement while measuring temperature. With a strong structural strength, polyimide can still exist stably in an environment of 400 °C and can be used for a long time in the temperature range of −200 to 300 °C [ 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 ].…”
Section: Sensors Coated With Polyimide Acrylate and Materials Fomentioning
confidence: 99%
See 2 more Smart Citations
“…Unlike PDMS, which is mostly used for temperature measurement, polyimide is mostly used for humidity measurement while measuring temperature. With a strong structural strength, polyimide can still exist stably in an environment of 400 °C and can be used for a long time in the temperature range of −200 to 300 °C [ 54 , 55 , 56 , 57 , 58 , 59 , 60 , 61 , 62 , 63 , 64 , 65 , 66 , 67 , 68 , 69 , 70 , 71 , 72 , 73 , 74 , 75 , 76 ].…”
Section: Sensors Coated With Polyimide Acrylate and Materials Fomentioning
confidence: 99%
“…The FBG coated with polymer had the biggest value of 48 pm/°C, which was 10 times bigger than that of the bare FBG. The same type of experiment was conducted in [ 60 ], where different materials, such as Ni, Cu, Zn, and Sn, were coated on the FBGs [ 60 ]. The temperature sensitivities of them were 1.5 times, 2 times, 2.5 times, and 3 times more than that of the bare FBG, respectively [ 60 ].…”
Section: Sensors Coated With Polyimide Acrylate and Materials Fomentioning
confidence: 99%
See 1 more Smart Citation
“…Jang and Kim [22] presented a methodology of impact-induced delamination assessment using FBG sensor. Li et al [23] investigated the temperature sensitivity of FBG sensors coated with metals during a dynamic cooling process. Davis and Kersey [24] presented an interrogation technique based on a wavelength division coupler to detect the wavelength shift of FBG sensor.…”
Section: Introductionmentioning
confidence: 99%
“…Several aspects including the detection range, temperature sensitivity, stability, and reliability are crucial for greater performance of the FBG temperature sensor. Various methods have been reported for instance FBG coated with different materials to improve the temperature sensitivity [1,2]. Meanwhile, intense studies have been performed to develop the FBG sensor that are robust and reliable in dynamic environment [3].…”
Section: Introductionmentioning
confidence: 99%